Literature DB >> 8186591

One Herbert double-threaded compression screw fixation of displaced type II odontoid fractures.

K W Chang1, Y W Liu, P G Cheng, L Chang, K L Suen, W L Chung, U L Chen, P L Liang.   

Abstract

Surgical treatment of type II odontoid fractures (OFs) has usually entailed C1-2 arthrodesis rather than fracture fixation. An alternative treatment of direct screw fixation is used to treat the fractures for preservation of atlantoaxial rotation. Type II OFs that cannot be completely reduced by close means are generally believed to be a contraindication for anterior screw fixation. Seven patients (group I) with displaced type II OFs that could be completely reduced were treated with fracture fixation by one 4.5-mm double-threaded compression screw and five patients (group II) with displaced type II OFs that could only be partially reduced were treated with fracture fixation by one 3.0-mm double-threaded compression screw. All patients had a minimum of 1-year follow-up. No major complications occurred. No loss of reduction occurred in group I patients. Group II patients had an average loss of reduction of 0.8 mm anterior displacement and 5 degrees anterior angulation. The overall rate of fracture union was 100%, and fracture resolution averaged 4.1 months. Ten patients had a normal range of cervical rotation, and there was no difference in preservation of cervical rotation between the two groups. Our results suggest that close reduction and compressive osteosynthesis by one double-threaded compression screw is an optimal method of treatment for displaced type II OFs that can be completely reduced and for some cases that can only be partially reduced. A 100% rate of fracture union and preservation of cervical rotation are the major advantages of this method. However, significant complications have been reported by other investigators. (ABSTRACT TRUNCATED AT 250 WORDS)

Entities:  

Mesh:

Year:  1994        PMID: 8186591     DOI: 10.1097/00002517-199407010-00009

Source DB:  PubMed          Journal:  J Spinal Disord        ISSN: 0895-0385


  13 in total

1.  One-screw fixation provides similar stability to that of two-screw fixation for type II dens fractures.

Authors:  Gang Feng; Robert Wendlandt; Sebastian Spuck; Arndt P Schulz
Journal:  Clin Orthop Relat Res       Date:  2012-05-15       Impact factor: 4.176

Review 2.  The impact of odontoid screw fixation techniques on screw-related complications and fusion rates: a systematic review and meta-analysis.

Authors:  Ivan Lvov; Andrey Grin; Aleksandr Talypov; Ivan Godkov; Anton Kordonskiy; Ulugbek Khushnazarov; Vladimir Smirnov; Vladimir Krylov
Journal:  Eur Spine J       Date:  2020-06-15       Impact factor: 3.134

3.  Efficacy of anterior odontoid screw fixation in the elderly patient: a CT-based biometrical analysis of odontoid fractures.

Authors:  Michael Mayer; Juliane Zenner; Alexander Auffarth; Jörg Atzwanger; Franz Romeder; Wolfgang Hitzl; Stefan Lederer; Herbert Resch; Heiko Koller
Journal:  Eur Spine J       Date:  2011-05-24       Impact factor: 3.134

Review 4.  The best surgical treatment for type II fractures of the dens is still controversial.

Authors:  Vincenzo Denaro; Rocco Papalia; Alberto Di Martino; Luca Denaro; Nicola Maffulli
Journal:  Clin Orthop Relat Res       Date:  2011-03       Impact factor: 4.176

5.  C2-fractures: part I. Quantitative morphology of the C2 vertebra is a prerequisite for the radiographic assessment of posttraumatic C2-alignment and the investigation of clinical outcomes.

Authors:  Heiko Koller; Frank Acosta; Mark Tauber; Elisabeth Komarek; Michael Fox; Mido Moursy; Wolfgang Hitzl; Herbert Resch
Journal:  Eur Spine J       Date:  2009-02-19       Impact factor: 3.134

6.  C2-fractures: part II. A morphometrical analysis of computerized atlantoaxial motion, anatomical alignment and related clinical outcomes.

Authors:  Heiko Koller; Frank Acosta; Rosemarie Forstner; Juliane Zenner; Herbert Resch; Mark Tauber; Stefan Lederer; Alexander Auffarth; Wolfgang Hitzl
Journal:  Eur Spine J       Date:  2009-02-18       Impact factor: 3.134

7.  Anatomical study of axis for odontoid screw thickness, length, and angle.

Authors:  Kagan Tun; Erkan Kaptanoglu; Berker Cemil; Mehmet Yorubulut; S Tuna Karahan; Ibrahim Tekdemir
Journal:  Eur Spine J       Date:  2008-11-13       Impact factor: 3.134

8.  Computerized Tomography-Based Morphometric Analysis of Odontoid in 100 Egyptian Patients.

Authors:  Nirmal D Patil; Mohammad Essam; Raafat Kamal Ragab; Hesham Elsaghir
Journal:  Int J Spine Surg       Date:  2020-02-29

9.  Pooled analysis of non-union, re-operation, infection, and approach related complications after anterior odontoid screw fixation.

Authors:  Nai-Feng Tian; Xu-Qi Hu; Li-Jun Wu; Xin-Lei Wu; Yao-Sen Wu; Xiao-Lei Zhang; Xiang-Yang Wang; Yong-Long Chi; Fang-Min Mao
Journal:  PLoS One       Date:  2014-07-24       Impact factor: 3.240

10.  Biomechanical Comparison of Inter-fragmentary Compression Pressures: Lag Screw versus Herbert Screw for Anterior Odontoid Screw Fixation.

Authors:  Jin-Woo Park; Kyoung-Tae Kim; Joo-Kyung Sung; Seong-Hyun Park; Ki-Woong Seong; Dae-Chul Cho
Journal:  J Korean Neurosurg Soc       Date:  2017-08-30
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.