Literature DB >> 19005694

Anatomical study of axis for odontoid screw thickness, length, and angle.

Kagan Tun1, Erkan Kaptanoglu, Berker Cemil, Mehmet Yorubulut, S Tuna Karahan, Ibrahim Tekdemir.   

Abstract

Anterior odontoid screw fixation is a safe and effective method for treatment of odontoid fractures. The screw treads should fit into the odontoid medulla, should pass the fracture line, and should pull fractured odontoid tip against body of axis in order to achieve optimum screw placement and treatment. This study has demonstrated optimal anterior odontoid screw thickness, length, and optimal angle for safe and strong anterior odontoid screw placement. Dry bone axis vertebrae were evaluated by direct measurements, X-ray measurements, and computerized tomography (CT) measurements. The screw thickness (inner diameter of the odontoid) was measured as well as screw length (distance between anterior-inferior point body of axis and tip of odontoid), and screw angle (the angle between basis of axis and tip of odontoid). The inner diameter of odontoid bone was measured as 6.5+/-1.9 mm, the screw length was 37.6+/-3.3 mm, and the screw angle was 62.4+/-4.7 on CT. There was no statistical difference between X-ray and CT in the measurements of screw thickness and angle. X-ray and CT measurements are both safe methods to determine the inner odontoid diameter and angle preoperatively. Screw length should be measured on CT only. To provide safe and strong anterior odontoid screw fixation, screw thickness, length, and angle should be known preoperatively, and these can be measured on X-ray and CT.

Entities:  

Mesh:

Year:  2008        PMID: 19005694      PMCID: PMC2899344          DOI: 10.1007/s00586-008-0814-7

Source DB:  PubMed          Journal:  Eur Spine J        ISSN: 0940-6719            Impact factor:   3.134


  19 in total

Review 1.  Spine update: cervical spine internal fixation using screw and screw-plate constructs.

Authors:  G M McCullen; S R Garfin
Journal:  Spine (Phila Pa 1976)       Date:  2000-03-01       Impact factor: 3.468

2.  Quantitative internal dens morphology.

Authors:  J G Heller; M D Alson; M B Schaffler; S R Garfin
Journal:  Spine (Phila Pa 1976)       Date:  1992-08       Impact factor: 3.468

3.  Morphology of the dens. A quantitative study.

Authors:  M B Schaffler; M D Alson; J G Heller; S R Garfin
Journal:  Spine (Phila Pa 1976)       Date:  1992-07       Impact factor: 3.468

4.  Fractures of the odontoid process of the axis.

Authors:  L D Anderson; R T D'Alonzo
Journal:  J Bone Joint Surg Am       Date:  1974-12       Impact factor: 5.284

5.  Single-screw fixation for acute Type II odontoid fracture.

Authors:  A Alfieri
Journal:  J Neurosurg Sci       Date:  2001-03       Impact factor: 2.279

6.  Epidemiology of spinal cord injury after acute odontoid fractures.

Authors:  J S Harrop; A D Sharan; G J Przybylski
Journal:  Neurosurg Focus       Date:  2000-06-15       Impact factor: 4.047

7.  Anterior instrumentation for traumatic C1-C2 instability.

Authors:  Rudy Reindl; Milan Sen; Max Aebi
Journal:  Spine (Phila Pa 1976)       Date:  2003-09-01       Impact factor: 3.468

8.  One Herbert double-threaded compression screw fixation of displaced type II odontoid fractures.

Authors:  K W Chang; Y W Liu; P G Cheng; L Chang; K L Suen; W L Chung; U L Chen; P L Liang
Journal:  J Spinal Disord       Date:  1994-02

9.  Fractures of the dens in adult patients.

Authors:  A D Hanssen; M E Cabanela
Journal:  J Trauma       Date:  1987-08

10.  Biomechanics of odontoid fracture fixation. Comparison of the one- and two-screw technique.

Authors:  R Sasso; B J Doherty; M J Crawford; M H Heggeness
Journal:  Spine (Phila Pa 1976)       Date:  1993-10-15       Impact factor: 3.468

View more
  10 in total

1.  Is All Anterior Oblique Fracture Orientation Really a Contraindication to Anterior Screw Fixation of Type II and Rostral Shallow Type III Odontoid Fractures?

Authors:  Dae-Chul Cho; Joo-Kyung Sung
Journal:  J Korean Neurosurg Soc       Date:  2011-06-30

2.  Feasibility of anterior screw fixation in children: a tomographic study.

Authors:  Lívia Gaspar Fernandes; Alexandre Fogaça Cristante; Raphael Martus Marcon; Tarcísio Eloy Pessoa de Barros Filho; Olavo Biraghi Letaif
Journal:  Eur Spine J       Date:  2018-02-09       Impact factor: 3.134

3.  Anatomy of the dens and its implications for fracture treatment: an anatomical and radiological study.

Authors:  J Štulík; G Hodasová; M Podhráský; P Nesnídal; P Fojtík; O Naňka
Journal:  Eur Spine J       Date:  2018-10-22       Impact factor: 3.134

4.  The odontoid process: various configuration types in MR examinations.

Authors:  Evangelos Perdikakis; Nikolaos Skoulikaris
Journal:  Eur Spine J       Date:  2013-12-24       Impact factor: 3.134

5.  Morphometric analysis of the odontoid process: using computed tomography--in the Greek population.

Authors:  D S Korres; J Lazaretos; J Papailiou; E Kyriakopoulos; D Chytas; N E Efstathopoulos; V S Nikolaou
Journal:  Eur J Orthop Surg Traumatol       Date:  2015-11-11

6.  Computerized Tomography-Based Morphometric Analysis of Odontoid in 100 Egyptian Patients.

Authors:  Nirmal D Patil; Mohammad Essam; Raafat Kamal Ragab; Hesham Elsaghir
Journal:  Int J Spine Surg       Date:  2020-02-29

7.  Morphometric parameters of the odontoid process of C2 vertebrae, in Indian population, a CT evaluation.

Authors:  Shankar Acharya; Manoj Kumar; Jay Deep Ghosh; Nitin Adsul; R S Chahal; K L Kalra
Journal:  Surg Neurol Int       Date:  2021-09-30

8.  Biomechanical Comparison of Inter-fragmentary Compression Pressures: Lag Screw versus Herbert Screw for Anterior Odontoid Screw Fixation.

Authors:  Jin-Woo Park; Kyoung-Tae Kim; Joo-Kyung Sung; Seong-Hyun Park; Ki-Woong Seong; Dae-Chul Cho
Journal:  J Korean Neurosurg Soc       Date:  2017-08-30

9.  Safe Margin beyond Dens Tips to Ventral Dura in Anterior Odontoid Screw Fixation : Analysis of Three-Dimensional Computed Tomography Scan of Odontoid Process.

Authors:  Min-Jae Sung; Kyoung-Tae Kim; Jeong-Hyun Hwang; Joo-Kyung Sung; Dae-Chul Cho
Journal:  J Korean Neurosurg Soc       Date:  2018-07-01

10.  Morphometric Evaluation of Craniocervical Junction by Magnetic Resonance Imaging Method.

Authors:  Mukadder Sunar; Samet Kapakin
Journal:  Asian J Neurosurg       Date:  2019 Jul-Sep
  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.