A regional convolution kernel algorithm for scatter correction in dual-energy images: comparison to single-kernel algorithms.

D G Kruger1, F Zink, W W Peppler, D L Ergun, C A Mistretta.   

Abstract

Single kernel scatter correction algorithms are based on the model that the scatter field can be predicted by convolution of the primary intensity (Iprim) with a spatially invariant scatter point-spread function (PSF). Practical limitations (Iprim unknown) suggest the substitution of the total detected intensity (Idet) for Iprim as the source image in the convolution. In regions of high scatter fraction (SF), Idet is a poor approximation of Iprim, thereby causing an overestimation of scatter originating in the region. This contributes to errors in estimating detected scatter in the mediastinum and neighboring regions. A technique using a regionally variable point-spread function that significantly reduces RMS error in estimation of the primary image as compared to the single PSF method is investigated. The regionally variable convolution method employs a larger PSF in the mediastinum and a smaller PSF in the lungs to reduce the error in estimating the scatter throughout the image. The method to allow for patient differences has also been expanded and various implementations of these methods have been compared. Results show that the dual-kernel algorithm is always more effective than an equivalent single-kernel algorithm. The dual-kernel algorithm using a predicted scatter fraction curve gives an overall RMS error in the primary of as low as 20.8% which is equivalent to 8.7% RMS error in the scatter. The dual-kernel method using a predicted scatter fraction curve approaches the accuracy of the single-kernel method using patient specific scatter measurements. Because using individual scatter measurements is a less desirable method for clinical use, we feel that the dual-kernel algorithm which uses two regions specific convolution kernels and a variable scatter fraction curve is the preferable method.

Entities:  

Mesh:

Year:  1994        PMID: 8177150     DOI: 10.1118/1.597297

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  5 in total

1.  An automatic and accurate x-ray tube focal spot/grid alignment system for mobile radiography: system description and alignment accuracy.

Authors:  David M Gauntt; Gary T Barnes
Journal:  Med Phys       Date:  2010-12       Impact factor: 4.071

2.  Scatter correction method for x-ray CT using primary modulation: phantom studies.

Authors:  Hewei Gao; Rebecca Fahrig; N Robert Bennett; Mingshan Sun; Josh Star-Lack; Lei Zhu
Journal:  Med Phys       Date:  2010-02       Impact factor: 4.071

3.  Dual-Energy Technique at Low Tube Voltages for Small Animal Imaging.

Authors:  Seungryong Cho; Emil Y Sidky; Junguo Bian; Xiaochuan Pan
Journal:  Tsinghua Sci Technol       Date:  2010-02       Impact factor: 2.016

4.  A practical cone-beam CT scatter correction method with optimized Monte Carlo simulations for image-guided radiation therapy.

Authors:  Yuan Xu; Ti Bai; Hao Yan; Luo Ouyang; Arnold Pompos; Jing Wang; Linghong Zhou; Steve B Jiang; Xun Jia
Journal:  Phys Med Biol       Date:  2015-04-10       Impact factor: 3.609

5.  Experimental study of intracranial hematoma detection with flat panel detector C-arm CT.

Authors:  H Arakawa; M P Marks; H M Do; D M Bouley; N Strobel; T Moore; R Fahrig
Journal:  AJNR Am J Neuroradiol       Date:  2008-01-17       Impact factor: 3.825

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.