Abstract

A novel algorithm was developed for computer aided diagnosis of microcalcification clusters in digital mammography. The method includes: (a) tree-structured central weighted median filters with variable shape windowing to suppress image noise but preserve image details; (b) a quasi range dispersion edge detector to increase edge contrast and definition; and (c) tree-structured wavelets for calcification segmentation. The preliminary evaluation of the method on nine mammograms showed that 100% sensitivity can be achieved at the expense of four false positive clusters per image. Research is ongoing for further optimization of the algorithm to reduce the number of false alarms and establish its clinical value.

Entities:  

Mesh:

Year:  1994        PMID: 8168064     DOI: 10.1016/0304-3835(94)90100-7

Source DB:  PubMed          Journal:  Cancer Lett        ISSN: 0304-3835            Impact factor:   8.679


  2 in total

Review 1.  Anniversary paper: History and status of CAD and quantitative image analysis: the role of Medical Physics and AAPM.

Authors:  Maryellen L Giger; Heang-Ping Chan; John Boone
Journal:  Med Phys       Date:  2008-12       Impact factor: 4.071

2.  Wavelet compression and segmentation of digital mammograms.

Authors:  B J Lucier; M Kallergi; W Qian; R A DeVore; R A Clark; E B Saff; L P Clarke
Journal:  J Digit Imaging       Date:  1994-02       Impact factor: 4.056