Literature DB >> 8167281

Intraoperative cardiac output monitoring: comparison of impedance cardiography and thermodilution.

A C Perrino1, A Lippman, C Ariyan, T Z O'Connor, M Luther.   

Abstract

Impedance cardiography (IC) is a noninvasive, simple to use method of cardiac output (CO) determination. A prospective evaluation of IC monitoring was performed in 50 patients undergoing noncardiac surgery. IC CO measurements (NC-COM3-Revision 7, BoMed Manufacturing) were compared to simultaneous measurements of thermodilution (TD) CO to assess the validity of this technique for intraoperative cardiac monitoring. Adequate impedance signals could not be obtained in 7 of the 50 patients. IC CO measurements were highly correlated to TD CO (P < .005), with a correlation coefficient r = 0.84. Bias analysis, however, indicated clinically significant disagreement between the two techniques. IC CO tended to underestimate TD CO (mean bias = -0.41 L/min) and the SD of the bias was 1.0 L/min (95% level of agreement 1.6 to -2.4 L/min). Trending data showed IC to accurately track the direction of TD CO changes but to underestimate their magnitude (r = 0.60, intercept -0.7 L/min, slope 0.47). Factors that may have impaired the performance of IC in this study include the high prevalence of cardiac disease in the study population and electrical noise in the operative setting. Further development of IC appears warranted if it is to prove useful as an intraoperative cardiac monitor.

Entities:  

Mesh:

Year:  1994        PMID: 8167281     DOI: 10.1016/1053-0770(94)90007-8

Source DB:  PubMed          Journal:  J Cardiothorac Vasc Anesth        ISSN: 1053-0770            Impact factor:   2.628


  7 in total

1.  Comparison between cardiac output measured by the pulmonary arterial thermodilution technique and that measured by the femoral arterial thermodilution technique in a pediatric animal model.

Authors:  M Rupérez; J López-Herce; C García; C Sánchez; E García; D Vigil
Journal:  Pediatr Cardiol       Date:  2003-12-23       Impact factor: 1.655

2.  Correlation between cardiac output measured by the femoral arterial thermodilution technique pulmonary arterial and that measured by contour pulse analysis in a paediatric animal model.

Authors:  Jesús López-Herce; Marta Rupérez; César Sánchez; Cristina García; Elena García
Journal:  J Clin Monit Comput       Date:  2006-02-28       Impact factor: 2.502

3.  Analysis of the accuracy of continuous thermodilution cardiac output measurement. Comparison with intermittent thermodilution and Fick cardiac output measurement.

Authors:  L Jacquet; G Hanique; D Glorieux; P Matte; M Goenen
Journal:  Intensive Care Med       Date:  1996-10       Impact factor: 17.440

4.  Evaluation of the effects of acupuncture on blood flow in humans with ultrasound color Doppler imaging.

Authors:  Shin Takayama; Masashi Watanabe; Hiroko Kusuyama; Satoru Nagase; Takashi Seki; Toru Nakazawa; Nobuo Yaegashi
Journal:  Evid Based Complement Alternat Med       Date:  2012-06-21       Impact factor: 2.629

5.  Haemodynamic changes in the superior mesenteric artery induced by acupuncture stimulation on the lower limbs.

Authors:  Masashi Watanabe; Shin Takayama; Yoshiko Yamamoto; Satoru Nagase; Takashi Seki; Nobuo Yaegashi
Journal:  Evid Based Complement Alternat Med       Date:  2012-05-23       Impact factor: 2.629

6.  Hemodynamic changes in the brachial artery induced by acupuncture stimulation on the lower limbs: a single-blind randomized controlled trial.

Authors:  Masashi Watanabe; Shin Takayama; Atsushi Hirano; Takashi Seki; Nobuo Yaegashi
Journal:  Evid Based Complement Alternat Med       Date:  2012-11-25       Impact factor: 2.629

7.  Accuracy, Precision, and Trending Ability of Electrical Cardiometry Cardiac Index versus Continuous Pulmonary Artery Thermodilution Method: A Prospective, Observational Study.

Authors:  P B W Cox; A M den Ouden; M Theunissen; L J Montenij; A G H Kessels; M D Lancé; W F F A Buhre; M A E Marcus
Journal:  Biomed Res Int       Date:  2017-10-09       Impact factor: 3.411

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.