X-ray scatter in megavoltage transmission radiography: physical characteristics and influence on image quality.

D A Jaffray1, J J Battista, A Fenster, P Munro.   

Abstract

The physical characteristics of x rays scattered by the patient and reaching the imaging detector, as well as their effect on verification (portal) image quality, were investigated for megavoltage (0.1-20 MeV) x-ray beams. Monte Carlo calculations and experimental measurements were used to characterize how the scatter and primary fluences at the detector plane were influenced by scattering geometry and the energy spectrum of the incident beam. The calculated scatter fluences were differentiated according to photon energy and scattering process. Scatter fractions were measured on a medical linear accelerator (Clinac 2100c, 6 MV) for a typical imaging geometry using an ionization chamber and a silicon diode. After correction for the energy dependence of the chamber and diode, the scatter fractions generated by the Monte Carlo simulations were found to be in excellent agreement with the measured results. In order to estimate the effect of scatter on image quality, the scatter and primary signals (i.e., energy deposited) produced in five different types of portal imaging detectors (lead plate/film, storage phosphor alone, lead plate/storage phosphor, compton recoil-electron detector, and a copper plate/Gd2O2S phosphor) were calculated. The results show that, for a specified geometry, the scatter fraction can vary by an order of magnitude, depending on the sensitivity of the imaging detector to low-energy (< 1 MeV) scattered radiation. For a common portal imaging detector (copper plate/Gd2O2S phosphor), the scattered radiation (i) reduced contrast by much as 50% for a fixed display-contrast system, and (ii) decreased the differential-signal-to-noise ratio (DSNR) by 10%-20% for a quantum-noise-limited portal imaging system. For currently available TV-camera-based portal imaging systems, which have variable display contrast, the reduction in DSNR depends on the light collection efficiency and the noise characteristics of the TV camera. Overall, these results show that scattered radiation can reduce contrast significantly in portal films while deteriorating image quality only moderately in on-line systems.

Entities:  

Mesh:

Year:  1994        PMID: 8164588     DOI: 10.1118/1.597255

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  6 in total

1.  A frequency-based approach to locate common structure for 2D-3D intensity-based registration of setup images in prostate radiotherapy.

Authors:  Reshma Munbodh; Zhe Chen; David A Jaffray; Douglas J Moseley; Jonathan P S Knisely; James S Duncan
Journal:  Med Phys       Date:  2007-07       Impact factor: 4.071

2.  Use of kilovoltage X-ray volume imaging in patient dose calculation for head-and-neck and partial brain radiation therapy.

Authors:  Weigang Hu; Jinsong Ye; Jiazhou Wang; Xuejun Ma; Zhen Zhang
Journal:  Radiat Oncol       Date:  2010-04-19       Impact factor: 3.481

3.  Guide to clinical use of electronic portal imaging.

Authors:  M G Herman; J J Kruse; C R Hagness
Journal:  J Appl Clin Med Phys       Date:  2000       Impact factor: 2.102

4.  A Simple Method for 2-D In Vivo Dosimetry by Portal Imaging.

Authors:  Stefano Peca; Derek Wilson Brown; Wendy Lani Smith
Journal:  Technol Cancer Res Treat       Date:  2017-06-06

5.  Feasibility of using two-dimensional array dosimeter for in vivo dose reconstruction via transit dosimetry.

Authors:  Heeteak Chung; Jonathan Li; Sanjiv Samant
Journal:  J Appl Clin Med Phys       Date:  2011-04-08       Impact factor: 2.102

6.  Impact of backscattered radiation from the bunker structure on EPID dosimetry.

Authors:  Pejman Rowshanfarzad; Mahsheed Sabet; Daryl J O'Connor; Peter B Greer
Journal:  J Appl Clin Med Phys       Date:  2012-11-08       Impact factor: 2.102

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.