Literature DB >> 8164579

Measurement of slice sensitivity profiles in spiral CT.

A Polacin1, W A Kalender, J Brink, M A Vannier.   

Abstract

In conventional computed tomography (CT), ramps, typically thin sheets of aluminum inclined at 45 degrees, are established tools for measurements of slice sensitivity profiles (SSP). In spiral CT, however, they yield inconsistent results for different positions along the longitudinal axis. It is explained herein how ramp profiles result as a superposition of true SSPs and artifacts, the artifacts being caused by the slice interpolation process due to the difficult interpolation condition in this particular geometry. In direct consequence, ramp tests yield spatially variant results. As an alternative tool for measuring the slice sensitivity profile, the use of a thin high-contrast sheet held between two disks which approximate the ideal test of a delta impulse in the longitudinal direction is suggested. Resulting SSPs are shown for both methods; the delta method, in agreement with theoretical predictions, provided smooth symmetrical SSPs independent of table position in agreement with theoretical predictions. It is concluded that ramps are inadequate test objects to determine SSPs in spiral CT.

Entities:  

Mesh:

Year:  1994        PMID: 8164579     DOI: 10.1118/1.597251

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  12 in total

1.  Application of CT-PSF-based computer-simulated lung nodules for evaluating the accuracy of computer-aided volumetry.

Authors:  Ayumu Funaki; Masaki Ohkubo; Shinichi Wada; Kohei Murao; Toru Matsumoto; Shinji Niizuma
Journal:  Radiol Phys Technol       Date:  2012-03-25

2.  Evaluation of the spatial resolution of multiplanar reconstruction images.

Authors:  Shohei Kudomi; Katsuhiko Ueda; Yasuyuki Ueda; Masateru Kawakubo; Taizo Sanada
Journal:  Radiol Phys Technol       Date:  2008-06-27

3.  Prospective, multireader evaluation of image quality and vascular delineation of multislice CT angiography of the brain.

Authors:  Birgit B Ertl-Wagner; Roland Bruening; Jeffrey Blume; Ralf-Thorsten Hoffmann; Brad Snyder; Karin A Herrmann; Maximilian F Reiser
Journal:  Eur Radiol       Date:  2005-03-19       Impact factor: 5.315

Review 4.  Anniversary paper. Development of x-ray computed tomography: the role of medical physics and AAPM from the 1970s to present.

Authors:  Xiaochuan Pan; Jeffrey Siewerdsen; Patrick J La Riviere; Willi A Kalender
Journal:  Med Phys       Date:  2008-08       Impact factor: 4.071

5.  A method for evaluating the performance of computer-aided detection of pulmonary nodules in lung cancer CT screening: detection limit for nodule size and density.

Authors:  Hajime Kobayashi; Masaki Ohkubo; Akihiro Narita; Janaka C Marasinghe; Kohei Murao; Toru Matsumoto; Shusuke Sone; Shinichi Wada
Journal:  Br J Radiol       Date:  2017-01-03       Impact factor: 3.039

6.  Observer-independent nodule-detectability index for low-dose lung cancer screening CT: a pilot study.

Authors:  Masaki Ohkubo; Shinichi Wada; Satoshi Kanai; Kazuhiro Ishikawa; Janaka C Marasinghe; Toru Matsumoto
Journal:  Radiol Phys Technol       Date:  2013-06-09

7.  A new method for determining the optimal CT threshold for extracting the upper airway.

Authors:  H Nakano; K Mishima; Y Ueda; A Matsushita; H Suga; Y Miyawaki; T Mano; Y Mori; Y Ueyama
Journal:  Dentomaxillofac Radiol       Date:  2012-07-27       Impact factor: 2.419

8.  Accurate determination of CT point-spread-function with high precision.

Authors:  Akihiro Kayugawa; Masaki Ohkubo; Shinichi Wada
Journal:  J Appl Clin Med Phys       Date:  2013-07-08       Impact factor: 2.102

9.  Optimal slice thickness for object detection with longitudinal partial volume effects in computed tomography.

Authors:  Pascal Monnin; Nicolas Sfameni; Achille Gianoli; Sandrine Ding
Journal:  J Appl Clin Med Phys       Date:  2016-11-23       Impact factor: 2.102

10.  Accuracy of lung nodule density on HRCT: analysis by PSF-based image simulation.

Authors:  Ken Ohno; Masaki Ohkubo; Janaka C Marasinghe; Kohei Murao; Toru Matsumoto; Shinichi Wada
Journal:  J Appl Clin Med Phys       Date:  2012-11-08       Impact factor: 2.102

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.