Literature DB >> 8160394

Stereopsis and positional acuity under dark adaptation.

M S Livingstone1, D H Hubel.   

Abstract

Though experience tells us we can perceive depth in dim light, it is not so obvious that one of the chief mechanisms for depth perception, stereopsis, is possible under scotopic conditions. The only studies on human stereopsis in the dark adapted state seem to be those of Nagel [(1902) Zeitschrift für Psychologie, 27, 264-266] and Mueller and Lloyd [(1948) Proceedings of the National Academy of Science, U.S.A., 34, 223-227], both of which used real objects or line stereograms. We tested stereopsis using both random-dot and line stereograms and, in agreement with these studies, found that stereopsis is indeed possible in dark adaptation. We also measured stereo acuity and positional acuity (both of which are examples of hyperacuity) and compared these with grating acuity at several levels of light and dark adaptation. At all illumination levels tested, acuities for stereopsis and relative line position were both higher than for grating acuity. As light levels decreased, positional and grating acuity declined in parallel fashion, whereas stereoacuity declined more steeply.

Entities:  

Mesh:

Year:  1994        PMID: 8160394     DOI: 10.1016/0042-6989(94)90217-8

Source DB:  PubMed          Journal:  Vision Res        ISSN: 0042-6989            Impact factor:   1.886


  5 in total

1.  Receptive field properties of neurons in the primary visual cortex under photopic and scotopic lighting conditions.

Authors:  Kevin R Duffy; David H Hubel
Journal:  Vision Res       Date:  2007-08-03       Impact factor: 1.886

2.  A New Distance Stereotest by Autostereoscopic Display Using an Eye-Tracking Method.

Authors:  Li-Qun Cao; Yuan-Qing Wang; Yuan Gao; Bi-Ye Zhou; Xue-Ling Li; Ke-Qiang Shen; Bin Xu; Ming-Gao Li
Journal:  Front Bioeng Biotechnol       Date:  2022-06-20

3.  Scotopic contour and shape discrimination using radial frequency patterns.

Authors:  Oliver J Flynn; Brett G Jeffrey
Journal:  J Vis       Date:  2019-02-01       Impact factor: 2.240

4.  A novel clinical dynamic stereopsis assessment based on autostereoscopic display system.

Authors:  Yiyao Wang; Jing Zhong; Mengyi Cheng; Jijing Li; Ke Ma; Xiaoqing Hu; Naiyang Li; Haowen Liang; Zhengyuan Zhu; Jianying Zhou; Jin Yuan
Journal:  Ann Transl Med       Date:  2022-06

5.  Objective Evaluation of Visual Fatigue Using Binocular Fusion Maintenance.

Authors:  Masakazu Hirota; Takeshi Morimoto; Hiroyuki Kanda; Takao Endo; Tomomitsu Miyoshi; Suguru Miyagawa; Yoko Hirohara; Tatsuo Yamaguchi; Makoto Saika; Takashi Fujikado
Journal:  Transl Vis Sci Technol       Date:  2018-03-23       Impact factor: 3.283

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.