Literature DB >> 8133990

Biomechanical evaluation of Caspar cervical screws: comparative stability under cyclical loading.

M R Gallagher1, D J Maiman, J Reinartz, F Pintar, N Yoganandan.   

Abstract

Anterior cervical instrumentation is used as an adjunct to bone fusion; however, definitive biomechanical data to support some applications and techniques are lacking. In the absence of supportive experimental data, posterior cortical penetration has been recommended with the Caspar system. Previously, we compared the axial pull-out strength of Caspar screws with and without posterior cortical penetration. This study compares the stability of unicortical versus bicortical screw penetration groups under cyclical loading simulating physiological flexion-extension. Caspar screws were placed in human cadaveric vertebrae with or without posterior cortical purchase. Each screw was separately tested, simulating flexion-extension to 200 cycles. Deformation time data allowed a direct comparison of screw "wobble" with and without posterior cortical purchase. The mean deformation differences between subcortical and bicortical groups were statistically significant and increased over time within both groups. Enhanced stability was noted with bicortical purchase throughout most of the examined range, becoming more pronounced over longer periods of cyclical loading. Significant (P < 0.05) increases in deformation over time were noted for both groups, suggesting potentially significant deterioration at the screw-bone interface, despite bicortical purchase. Such deterioration with repeated flexion-extension loading may be of concern in the use of Caspar plates in the presence of multicolumn instability.

Entities:  

Mesh:

Year:  1993        PMID: 8133990     DOI: 10.1227/00006123-199312000-00013

Source DB:  PubMed          Journal:  Neurosurgery        ISSN: 0148-396X            Impact factor:   4.654


  4 in total

1.  Biomechanical analysis of anterior cervical spine plate fixation systems with unicortical and bicortical screw purchase.

Authors:  Wolfgang Lehmann; Michael Blauth; Daniel Briem; Ulf Schmidt
Journal:  Eur Spine J       Date:  2003-12-17       Impact factor: 3.134

2.  Biomechanical comparison of anterior cervical spine locked and unlocked plate-fixation systems.

Authors:  Wolfgang Lehmann; Daniel Briem; Michael Blauth; Ulf Schmidt
Journal:  Eur Spine J       Date:  2004-06-10       Impact factor: 3.134

3.  Biomechanical evaluation of subcortical versus bicortical screw purchase in anterior cervical plating.

Authors:  I H Chen
Journal:  Acta Neurochir (Wien)       Date:  1996       Impact factor: 2.216

Review 4.  4- and 5-level anterior fusions of the cervical spine: review of literature and clinical results.

Authors:  Heiko Koller; Axel Hempfing; Luis Ferraris; Oliver Maier; Wolfgang Hitzl; Peter Metz-Stavenhagen
Journal:  Eur Spine J       Date:  2007-06-29       Impact factor: 3.134