Radiotherapy X-ray beam inhomogeneity corrections: the problem of lateral electronic disequilibrium in lung.

P E Metcalfe1, T P Wong, P W Hoban.   

Abstract

Accurate dose calculations in lung are important to assess lung and tumour dose in various radiotherapy cancer patients. Those patients of particular relevance are Ca lung and Ca Oesophagus patients because large volumes of lung are irradiated to high doses. In this paper, dosimetry results for megavoltage X-ray beams obtained in a lung phantom are compared with dose computations produced by (1) effective path length, (2) equivalent tissue-air ratio, (3) super-position/convolution and (4) Monte Carlo dose calculation methods. The mid-lung dose error at 10 MV for a 5 x 5 cm field is 10.0%, 6.7%, 1.9% and 0.6% respectively. Tests at the lower energy of 6 MV with a field size of 10 x 10 cm show a mid-lung error of only 2.0% for the equivalent tissue air ratio method. At this energy it appears that central axis dose voids are sufficiently small to enable the routine use of the equivalent tissue air ratio method. At the higher energies tested, 10 and 18 MV, this method is accurate. Superposition and Monte Carlo methods are presented which show good agreement with experimental results in a lung phantom even in regions of lateral electron disequilibrium.

Entities:  

Mesh:

Year:  1993        PMID: 8122987

Source DB:  PubMed          Journal:  Australas Phys Eng Sci Med        ISSN: 0158-9938            Impact factor:   1.430


  4 in total

1.  Technical note: Heterogeneity dose calculation accuracy in IMRT: study of five commercial treatment planning systems using an anthropomorphic thorax phantom.

Authors:  Scott E Davidson; Richard A Popple; Geoffrey S Ibbott; David S Followill
Journal:  Med Phys       Date:  2008-12       Impact factor: 4.071

2.  Endo-rectal balloon cavity dosimetry in a phantom: performance under IMRT and helical tomotherapy beams.

Authors:  Nicholas Hardcastle; Peter E Metcalfe; Anatoly B Rosenfeld; Wolfgang A Tomé
Journal:  Radiother Oncol       Date:  2009-03-30       Impact factor: 6.280

3.  Pinnacle3 modeling and end-to-end dosimetric testing of a Versa HD linear accelerator with the Agility head and flattening filter-free modes.

Authors:  Daniel L Saenz; Ganesh Narayanasamy; Wilbert Cruz; Nikos Papanikolaou; Sotirios Stathakis
Journal:  J Appl Clin Med Phys       Date:  2016-01-08       Impact factor: 2.102

4.  Evaluation of the analytical anisotropic algorithm in an extreme water-lung interface phantom using Monte Carlo dose calculations.

Authors:  Isabelle M Gagné; Sergei Zavgorodni
Journal:  J Appl Clin Med Phys       Date:  2006-06-16       Impact factor: 2.102

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.