Legionellaceae in the potable water of Nova Scotia hospitals and Halifax residences.

T Marrie1, P Green, S Burbridge, G Bezanson, S Neale, P S Hoffman, D Haldane.   

Abstract

Water was cultured from 39 of 48 hospitals (7 Halifax hospitals and 32 non-Halifax hospitals) in the province of Nova Scotia and from 90 residences (74 private dwellings, 16 apartments) in Halifax to determine the frequency of legionella contamination. Six of seven Halifax hospitals had Legionellaceae isolated from their potable water compared with 3 of 32 non-Halifax hospitals (P < 0.0001). Overall, 19 of 59 (32%) of the water samples from Halifax hospitals were positive for legionellae compared with 5 of 480 (1%) samples from non-Halifax hospitals (P < 0.0000). Five of the six positive Halifax hospitals had Legionella pneumophila serogroup 1 and 1 had L. longbeachae serogroup 2 recovered from their potable water. Legionella contamination was associated with older, larger (> or = 50 beds) hospitals with total system recirculation. These hospitals also had water with a higher pH and calcium content but lower sodium, potassium, nitrate, iron and copper content. Fourteen of the 225 (6.2%) water samples from Halifax residences were positive for legionellae -8% (6/74) of the single family dwellings were positive, compared with 25% (4/16) apartments. The positivity rate of 15.7% for the 19 electric hot-water heaters in Halifax homes was not significantly different from the 32% positivity for Halifax hospitals. L. longbeachae accounted for 2 of the 14 isolates of legionellae from Halifax homes.

Entities:  

Mesh:

Substances:

Year:  1994        PMID: 8119354      PMCID: PMC2271493          DOI: 10.1017/s0950268800057502

Source DB:  PubMed          Journal:  Epidemiol Infect        ISSN: 0950-2688            Impact factor:   2.451


  22 in total

1.  Legionella pneumophila in a hospital water system following a nosocomial outbreak: prevalence, monoclonal antibody subgrouping and effect of control measures.

Authors:  C D Ribeiro; S H Burge; S R Palmer; J O Tobin; I D Watkins
Journal:  Epidemiol Infect       Date:  1987-06       Impact factor: 2.451

2.  Legionella in hospital and hotel water supplies.

Authors:  C L Bartlett; J B Kurtz; J G Hutchison; G C Turner; A E Wright
Journal:  Lancet       Date:  1983-12-03       Impact factor: 79.321

3.  Legionella longbeachae pneumonia diagnosed by bronchial brushing.

Authors:  S Lam; J A Smith; J D Burton; R G Evelyn; B Harper; V Huckell; E A Jones
Journal:  Can Med Assoc J       Date:  1982-08-01       Impact factor: 8.262

4.  Effects of metals on Legionella pneumophila growth in drinking water plumbing systems.

Authors:  S J States; L F Conley; M Ceraso; T E Stephenson; R S Wolford; R M Wadowsky; A M McNamara; R B Yee
Journal:  Appl Environ Microbiol       Date:  1985-11       Impact factor: 4.792

5.  Pneumonia and acute pancreatitis most probably caused by a Legionella longbeachae infection.

Authors:  R Eitrem; A Forsgren; C Nilsson
Journal:  Scand J Infect Dis       Date:  1987

6.  Subtypes of Legionella pneumophila serogroup 1 associated with different attack rates.

Authors:  J F Plouffe; M F Para; W E Maher; B Hackman; L Webster
Journal:  Lancet       Date:  1983-09-17       Impact factor: 79.321

7.  Survival and multiplication of Legionella pneumophila in municipal drinking water systems.

Authors:  S J States; L F Conley; J M Kuchta; B M Oleck; M J Lipovich; R S Wolford; R M Wadowsky; A M McNamara; J L Sykora; G Keleti
Journal:  Appl Environ Microbiol       Date:  1987-05       Impact factor: 4.792

8.  Legionella pneumophila in residential water supplies: environmental surveillance with clinical assessment for Legionnaires' disease.

Authors:  J E Stout; V L Yu; Y C Yee; S Vaccarello; W Diven; T C Lee
Journal:  Epidemiol Infect       Date:  1992-08       Impact factor: 2.451

9.  Recognition of a second serogroup of Legionella longbeachae.

Authors:  W F Bibb; R J Sorg; B M Thomason; M D Hicklin; A G Steigerwalt; D J Brenner; M R Wulf
Journal:  J Clin Microbiol       Date:  1981-12       Impact factor: 5.948

10.  Legionella longbeachae species nova, another etiologic agent of human pneumonia.

Authors:  R M McKinney; R K Porschen; P H Edelstein; M L Bissett; P P Harris; S P Bondell; A G Steigerwalt; R E Weaver; M E Ein; D S Lindquist; R S Kops; D J Brenner
Journal:  Ann Intern Med       Date:  1981-06       Impact factor: 25.391

View more
  7 in total

1.  Risk factors for contamination of hotel water distribution systems by Legionella species.

Authors:  Varvara Mouchtouri; Emmanuel Velonakis; Andreas Tsakalof; Christina Kapoula; Georgia Goutziana; Alkiviadis Vatopoulos; Jenny Kremastinou; Christos Hadjichristodoulou
Journal:  Appl Environ Microbiol       Date:  2007-01-19       Impact factor: 4.792

2.  Comparison of large restriction fragments of Mycobacterium avium isolates recovered from AIDS and non-AIDS patients with those of isolates from potable water.

Authors:  T Aronson; A Holtzman; N Glover; M Boian; S Froman; O G Berlin; H Hill; G Stelma
Journal:  J Clin Microbiol       Date:  1999-04       Impact factor: 5.948

3.  Legionella pneumophila monoclonal antibody subgroups and DNA sequence types isolated in Canada between 1981 and 2009: Laboratory Component of National Surveillance.

Authors:  A R Reimer; S Au; S Schindle; K A Bernard
Journal:  Eur J Clin Microbiol Infect Dis       Date:  2009-12-04       Impact factor: 3.267

4.  Legionnaires' disease - Results of a multicentre Canadian study.

Authors:  Thomas J Marrie; Emidio De Carolis; Victor L Yu; Janet Stout
Journal:  Can J Infect Dis       Date:  2003-05

5.  Legionella prevalence and risk of legionellosis in Japanese households.

Authors:  T Kuroki; Y Watanabe; H Teranishi; S Izumiyama; J Amemura-Maekawa; F Kura
Journal:  Epidemiol Infect       Date:  2017-02-07       Impact factor: 4.434

Review 6.  Legionellosis Caused by Non-Legionella pneumophila Species, with a Focus on Legionella longbeachae.

Authors:  Stephen T Chambers; Sandy Slow; Amy Scott-Thomas; David R Murdoch
Journal:  Microorganisms       Date:  2021-01-31

7.  Compromised Effectiveness of Thermal Inactivation of Legionella pneumophila in Water Heater Sediments and Water, and Influence of the Presence of Vermamoeba vermiformis.

Authors:  Margot Cazals; Emilie Bédard; Margot Doberva; Sébastien Faucher; Michèle Prévost
Journal:  Microorganisms       Date:  2022-02-15
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.