| Literature DB >> 3595743 |
C D Ribeiro, S H Burge, S R Palmer, J O Tobin, I D Watkins.
Abstract
Swabs and water samples from a hospital water system were cultured for legionellae over an extended period. Legionella pneumophila serogroup 1, including outbreak associated strains, were isolated in small numbers from approximately 5% of these samples despite implementation of the current DHSS/Welsh Office regulations. No cases of nosocomial legionnaires' disease were proven during the study. Physical cleaning and chemical sterilization of taps, and replacement of washers with 'approved' brands did not eradicate the organisms. Eradication of legionellae in hospital water supplies appears to be unnecessary in preventing nosocomial legionnaires' disease provided the current DHSS/Welsh Office recommendations are implemented.Entities:
Mesh:
Substances:
Year: 1987 PMID: 3595743 PMCID: PMC2235364 DOI: 10.1017/s0950268800062002