Literature DB >> 8119041

Tibial plateau coverage in total knee arthroplasty.

S J Incavo1, P J Ronchetti, J G Howe, J P Tranowski.   

Abstract

Optimizing coverage of the resected tibial plateau is an important consideration in total knee arthroplasty. The tibial coverage of eight different tibial tray designs was examined in 35 resected tibial specimens. When no component overlap was permitted, the average tibial coverage of the different designs ranged from 76.4% to 80.8%. When the component was allowed slight overlap, a "surgical fit," the average coverage ranged from 78.5% to 85.5%. As a group, the six symmetric designs provided more coverage than the two asymmetric designs (p < 0.05). Areas of poor coverage were identified, and different tray geometries were compared. Asymmetric tibial components are thought to be more anatomic in nature and therefore cover the tibial plateau surface more completely than symmetric components. The results of this study do not support this, and in fact demonstrate that symmetric components can provide more coverage when compared with two asymmetric component designs.

Mesh:

Year:  1994        PMID: 8119041

Source DB:  PubMed          Journal:  Clin Orthop Relat Res        ISSN: 0009-921X            Impact factor:   4.176


  22 in total

1.  Anthropometric measurements of tibial plateau and correlation with the current tibial implants.

Authors:  Omer Faruk Erkocak; Fatih Kucukdurmaz; Safak Sayar; Mehmet Emin Erdil; Hasan Huseyin Ceylan; Ibrahim Tuncay
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2015-04-24       Impact factor: 4.342

2.  Primary stability of tibial components in TKA: in vitro comparison of two cementing techniques.

Authors:  Adrian Skwara; J Figiel; T Knott; J R J Paletta; S Fuchs-Winkelmann; C O Tibesku
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2009-07-02       Impact factor: 4.342

3.  Is there any relation between distal parameters of the femur and its height and width?

Authors:  Fatih Yazar; Nurcan Imre; Bilal Battal; Serkan Bilgic; Cem Tayfun
Journal:  Surg Radiol Anat       Date:  2011-07-08       Impact factor: 1.246

4.  Rotational alignment of the tibial component in total knee arthroplasty: the anterior tibial cortex is a reliable landmark.

Authors:  Andrea Baldini; Pier Francesco Indelli; Lapo DE Luca; Pierpaolo Cerulli Mariani; Massimiliano Marcucci
Journal:  Joints       Date:  2014-03-21

5.  Maximizing tibial coverage is detrimental to proper rotational alignment.

Authors:  Stacey Martin; Alex Saurez; Sabir Ismaily; Kashif Ashfaq; Philip Noble; Stephen J Incavo
Journal:  Clin Orthop Relat Res       Date:  2014-01       Impact factor: 4.176

6.  Tibial component coverage and rotational alignment accuracy after mobile-bearing total knee arthroplasty.

Authors:  Yoshinori Ishii; Hideo Noguchi; Junko Sato; Hana Ishii; Koji Todoroki; Shin-Ichi Toyabe
Journal:  Eur J Orthop Surg Traumatol       Date:  2018-02-10

7.  Retrospective study of asymmetric vs symmetric tibial plates and ultracongruent vs posterior stabilized inserts in Indian population: An Indian experience of Natural Knee II.

Authors:  Ajay Deep Singh
Journal:  J Clin Orthop Trauma       Date:  2016-07-26

8.  Intraoperative anthropometric measurements of tibial morphology: comparisons with the dimensions of current tibial implants.

Authors:  Bo Yang; Chang-hui Song; Jia-kuo Yu; Yong-qiang Yang; Xi Gong; Lian-xu Chen; Yong-jian Wang; Jian Wang
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2014-09-02       Impact factor: 4.342

9.  Evaluation of the rotational alignment of the tibial component in total knee arthroplasty: position prioritizing maximum coverage.

Authors:  Masashi Hirakawa; Masashi Miyazaki; Shinichi Ikeda; Yoshiki Matsumoto; Makoto Kondo; Hiroshi Tsumura
Journal:  Eur J Orthop Surg Traumatol       Date:  2016-09-10

10.  Lateral versus medial tibial plateau: morphometric analysis and adaptability with current tibial component design.

Authors:  E Servien; M Saffarini; S Lustig; S Chomel; Ph Neyret
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2008-09-09       Impact factor: 4.342

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.