Literature DB >> 8119035

Wear patterns on retrieved polyethylene tibial inserts and their relationship to technical considerations during total knee arthroplasty.

R C Wasielewski1, J O Galante, R M Leighty, R N Natarajan, A G Rosenberg.   

Abstract

Fifty-five unconstrained polyethylene tibial inserts were retrieved at revision total knee arthroplasty and examined for evidence of wear after a mean implantation time of 34.2 months (2.5-80 months). Twenty inserts were ultra-high molecular weight polyethylene (UHMWPE) and 35 were carbon-reinforced polyethylene. Topographic maps of the articular and metal-backed surfaces of each component were constructed to characterize the extent and location of polyethylene degradation, identified visually by mode. In 32 of the retrieved inserts, pre- and postarthroplasty or prerevision radiographs were analyzed for component positioning, sizing, and extremity alignment. These factors then were compared with the patterns and severity of polyethylene wear on the inserts to establish correlations. Severe generalized articular wear was seen in inserts with third body wear from patellar metal-backed failure and cement debris. Severe localized delamination wear was seen in inserts with rotational-subluxation patterns of wear (p = 0.05). The external rotation subluxation wear pattern was strongly associated with knees that had lateral subluxation of the patella (p = 0.0002). Articular wear and cold flow into screw holes tended to be greater in the tightest prearthroplasty compartment (medial in the varus knee [p = 0.0157]; lateral in the valgus knees [p = 0.0226]). Fourteen of 16 knees with a preoperative varus deformities--even when corrected to a normal postarthroplasty anatomic axis--still had greater medial compartment articular wear (p = 0.001). Twelve of these knees did not have a medial release at the time of initial arthroplasty. Preoperative varus also was found to be related to the occurrence of posteromedial cold flow of polyethylene into tibial tray screw holes (p = 0.007). Increasing tibial insert posterior slope was associated with increasingly posterior articular wear track location (p = 0.03). This study indicates that unconstrained tibial component wear patterns and severity may be associated with clinical and mechanical factors under the surgeon's control, including component size and position, and knee alignment and ligament balance.

Entities:  

Mesh:

Substances:

Year:  1994        PMID: 8119035

Source DB:  PubMed          Journal:  Clin Orthop Relat Res        ISSN: 0009-921X            Impact factor:   4.176


  110 in total

1.  [Total knee arthroplasty--navigation as the standard].

Authors:  L Kinzl; F Gebhard; P Keppler
Journal:  Chirurg       Date:  2004-10       Impact factor: 0.955

2.  Does total knee arthroplasty change frontal plane knee biomechanics during gait?

Authors:  Karl F Orishimo; Ian J Kremenic; Ajit J Deshmukh; Stephen J Nicholas; Jose A Rodriguez
Journal:  Clin Orthop Relat Res       Date:  2011-11-29       Impact factor: 4.176

3.  Comparison of the tibiofemoral rotational alignment after mobile and fixed bearing total knee arthroplasty.

Authors:  Dongwook Kim; Sang Cheol Seong; Myung Chul Lee; Sahnghoon Lee
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2011-11-06       Impact factor: 4.342

4.  Comparative study of tibial posterior slope angle following cruciate-retaining total knee arthroplasty using one of three implants.

Authors:  Dae Kyung Bae; Sang Jun Song; Kyoung Ho Yoon; Jung Ho Noh; Seong Cheol Moon
Journal:  Int Orthop       Date:  2011-12-06       Impact factor: 3.075

5.  Surface damage versus tibial polyethylene insert conformity: a retrieval study.

Authors:  Markus A Wimmer; Michel P Laurent; Jeannie D Haman; Joshua J Jacobs; Jorge O Galante
Journal:  Clin Orthop Relat Res       Date:  2012-07       Impact factor: 4.176

6.  Relationship between the tibial anteroposterior axis and the surgical epicondylar axis in varus and valgus knees.

Authors:  Shinya Kawahara; Shuichi Matsuda; Ken Okazaki; Yasutaka Tashiro; Hiroaki Mitsuyasu; Hiroyuki Nakahara; Yukihide Iwamoto
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2011-12-29       Impact factor: 4.342

Review 7.  Alignment outcomes in navigated total knee arthroplasty: a meta-analysis.

Authors:  Yonghui Fu; Mingming Wang; Yifeng Liu; Qin Fu
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2011-10-15       Impact factor: 4.342

8.  Robotic-assisted TKA reduces postoperative alignment outliers and improves gap balance compared to conventional TKA.

Authors:  Eun-Kyoo Song; Jong-Keun Seon; Ji-Hyeon Yim; Nathan A Netravali; William L Bargar
Journal:  Clin Orthop Relat Res       Date:  2013-01       Impact factor: 4.176

9.  Sagittal alignment of the lower extremity while standing in female.

Authors:  Ryo Sugama; Yukihide Minoda; Akio Kobayashi; Hiroyoshi Iwaki; Mitsuhiko Ikebuchi; Yusuke Hashimoto; Kunio Takaoka; Hiroaki Nakamura
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2010-04-21       Impact factor: 4.342

10.  Medial parapatellar approach leads to internal rotation of tibial component in total knee arthroplasty.

Authors:  Filippo-Franco Schiapparelli; Felix Amsler; Michael T Hirschmann
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2017-05-30       Impact factor: 4.342

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.