Polyethylene wear in unicompartmental knee arthroplasty.

R E Bartley1, S D Stulberg, W J Robb, H J Sweeney.   

Abstract

From 1983 to 1989, 147 unicompartmental knee arthroplasties (UKA) were performed. Eighteen knees (13%) have required revision: there were 11 (37%) Porous Coated Anatomic (PCA), three (8%) Microloc, and four (17%) Fibermesh UKAs. Retrieved implants were examined to determine the pattern and extent of polyethylene wear. Wear was severe in each series and was characterized by delamination, pitting, peripheral cracking, deformation, and abrasion. Polyethylene failure appeared to result from large localized stresses resulting from lack of conformity of the articular geometries of the prostheses. Progressive subluxation of the implants occurred that produced very high localized contact stresses at the periphery of the tibial component where the polyethylene was thinnest. The progression of osteoarthritis in these knees, particularly the attenuation of the anterior cruciate ligament, increased the tendency of these incongruous implants to subluxate. Although changes in the design and manufacturing of unicompartmental knee arthroplasties may increase the resistance of these implants to polyethylene wear, the progression of osteoarthritis at an unpredictable rate is likely to be associated with persistent polyethylene wear in this type of arthroplasty.

Entities:  

Mesh:

Substances:

Year:  1994        PMID: 8119016

Source DB:  PubMed          Journal:  Clin Orthop Relat Res        ISSN: 0009-921X            Impact factor:   4.176


  12 in total

1.  [AMC unicondylar prosthesis].

Authors:  G Saxler; D Temmen; G Bontemps
Journal:  Orthopade       Date:  2004-11       Impact factor: 1.087

2.  Severe metallosis after unicompartmental knee arthroplasty.

Authors:  Vicente Sanchis-Alfonso
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2006-10-07       Impact factor: 4.342

3.  Anteroposterior and rotational stability in fixed and mobile bearing unicondylar knee arthroplasty: a cadaveric study using the robotic force sensor system.

Authors:  Roland Becker; Christian Mauer; Christian Stärke; Mathias Brosz; Thore Zantop; Christoph H Lohmann; Martin Schulze
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2012-08-07       Impact factor: 4.342

4.  The coronal alignment after medial unicompartmental knee arthroplasty can be predicted: usefulness of full-length valgus stress radiography for evaluating correctability.

Authors:  Yasutaka Tashiro; Shuichi Matsuda; Ken Okazaki; Hideki Mizu-Uchi; Umito Kuwashima; Yukihide Iwamoto
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2014-08-26       Impact factor: 4.342

5.  Lateral unicompartmental knee replacement: a systematic review of reasons for failure.

Authors:  Lukas Ernstbrunner; Mohamed A Imam; Octavian Andronic; Tabea Perz; Karl Wieser; Sandro F Fucentese
Journal:  Int Orthop       Date:  2017-10-13       Impact factor: 3.075

6.  Exposure of articular chondrocytes to wear particles induces phagocytosis, differential inflammatory gene expression, and reduced proliferation.

Authors:  Michael D Kurdziel; Meagan Salisbury; Lige Kaplan; Tristan Maerz; Kevin C Baker
Journal:  J Mater Sci Mater Med       Date:  2017-05-22       Impact factor: 3.896

7.  Combined unicompartmental knee arthroplasty and anterior cruciate ligament reconstruction.

Authors:  Marco Tinius; Pierre Hepp; Roland Becker
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2011-05-11       Impact factor: 4.342

8.  Retrieved Unicompartmental Implants with Full PE Tibial Components: The Effects of Knee Alignment and Polyethylene Thickness on Creep and Wear.

Authors:  Ph Hernigou; A Poignard; P Filippini; S Zilber
Journal:  Open Orthop J       Date:  2008-04-11

9.  Rupture of the femoral component and severe metallosis of the knee 10 years after unicompartmental knee arthroplasty (UKA): a case report.

Authors:  Eugenio Vecchini; Alessandro Ditta; Margherita Gelmini; Tommaso Maluta; Roberto Valentini; Matteo Ricci; Bruno Magnan
Journal:  Acta Biomed       Date:  2019-01-10

10.  More Anterior in vivo Contact Position in Patients With Fixed-Bearing Unicompartmental Knee Arthroplasty During Daily Activities Than in vitro Wear Simulator.

Authors:  Huiyong Dai; Nan Zheng; Diyang Zou; Zhemin Zhu; Ming Han Lincoln Liow; Tsung-Yuan Tsai; Qi Wang
Journal:  Front Bioeng Biotechnol       Date:  2021-05-20
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.