Literature DB >> 8113253

Hip replacement with a threaded acetabular cup. A follow-up study.

G M Fox1, A A McBeath, J P Heiner.   

Abstract

A study was begun in 1983 to determine the efficacy of a threaded acetabular cup. Fifty-five patients who had a total of sixty-eight threaded titanium cups had a complete clinical and radiographic evaluation yearly. Fifty-two of the arthroplasties had been primary and sixteen, revisions. The average duration of follow-up was six years (range, five to nine years). Seventeen cups had to be revised at an average of sixty-two months (range, twenty-seven to 108 months) after the index operation. Nine additional cups were loose and revision was pending at the most recent follow-up examination. Failure was defined as revision or pending revision. Thus, twenty-six (38 per cent) of the sixty-eight cups failed. Sixteen (31 per cent) of the fifty-two primary arthroplasties failed and ten of the sixteen revision arthroplasties failed. Radiographic changes that were evident in patients who had a failed cup consisted of superomedial migration of the cup with osteolysis in Zone 3, as classified by DeLee and Charnley. These radiographic changes preceded symptoms in most patients. Because of the high rate of failure of this acetabular component at six years, we believe that its use is not warranted.

Entities:  

Mesh:

Substances:

Year:  1994        PMID: 8113253     DOI: 10.2106/00004623-199402000-00005

Source DB:  PubMed          Journal:  J Bone Joint Surg Am        ISSN: 0021-9355            Impact factor:   5.284


  4 in total

1.  Long-term results of the threaded Mecron cup in primary total hip arthroplasty : A 15-20-year follow-up study.

Authors:  Michael Clarius; Alexander W Jung; Marcus R Streit; Christian Merle; Patric Raiss; Peter R Aldinger
Journal:  Int Orthop       Date:  2009-07-24       Impact factor: 3.075

2.  Long-term results of the threaded Weill cup in primary total hip arthroplasty: a 15-20-year follow-up study.

Authors:  Michael Clarius; Alexander W Jung; Patric Raiss; Marcus R Streit; Christian Merle; Peter R Aldinger
Journal:  Int Orthop       Date:  2009-07-24       Impact factor: 3.075

3.  Cementless Hip Arthroplasty in Southern Iran, Midterm Outcome and Comparison of Two Designs.

Authors:  Gholam Hossein Shahgheraghi; Frcs C Seyed Ali Hashemi
Journal:  Iran J Med Sci       Date:  2015-09

4.  Failure of Polyethylene Inlays in Cementless Total Hip Arthroplasty: A Retrieval Analysis.

Authors:  Ulrike Mueller; Christoph Lee; Christian Heisel; Marc Thomsen; Rudi G Bitsch; J Philippe Kretzer
Journal:  Biomed Res Int       Date:  2016-08-31       Impact factor: 3.411

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.