Literature DB >> 8111585

Aerosol deposition in mechanically ventilated patients. Optimizing nebulizer delivery.

T G O'Riordan1, L B Palmer, G C Smaldone.   

Abstract

Previous studies have suggested that nebulizers are inefficient in delivering aerosolized medication to the lung in patients supported by mechanical ventilation. In a recent bench study, we characterized factors that may affect aerosol delivery, i.e., nebulizer type, ventilator settings (duty cycle), volume fill, and humidification as well as technical factors affecting measurement of deposition (e.g., radiolabeled compounds). Utilizing the predictions from our bench data, the present study was designed to assess nebulized aerosol delivery to ventilated patients under optimal conditions. Seven patients who were receiving mechanical ventilation (Bear II) via tracheostomy tube (TT) were studied. The humidifier was turned off. The test aerosol, a saline solution labeled with 99mTechnetium bound to human serum albumin (99mTc-HSA), was administered via a jet nebulizer (AeroTech II, 1.1 +/- 1.8 microns [mass median aerodynamic diameter, MMAD, geometric standard deviation, sigma g]), which was incorporated into the ventilator circuit and run to dryness. Inhaled and deposited radioactivity were measured by a mass balance/filter technique. TT versus lung deposition were quantified by removal of the inner cannula and direct measurement of TT deposition in a well counter. Inspiratory versus expiratory components of TT deposition were separated via bench techniques for each TT tube and breathing pattern. The regional distribution of deposited radioactivity was confirmed by gamma camera scans before and after TT removal. Measured radioactivity at each site was expressed as a percentage of nebulizer charge (i.e., the quantity of radioactivity originally placed in the nebulizer). On average, 30.6 +/- 6.3% (SD) of the charge was inhaled by the ventilated patients. Mean deposition in the TT during inspiration was 2.6 +/- 0.5%.(ABSTRACT TRUNCATED AT 250 WORDS)

Entities:  

Mesh:

Substances:

Year:  1994        PMID: 8111585     DOI: 10.1164/ajrccm.149.1.8111585

Source DB:  PubMed          Journal:  Am J Respir Crit Care Med        ISSN: 1073-449X            Impact factor:   21.405


  12 in total

Review 1.  Aerosol delivery to ventilated newborn infants: historical challenges and new directions.

Authors:  Jan Mazela; Richard A Polin
Journal:  Eur J Pediatr       Date:  2010-09-28       Impact factor: 3.183

2.  Comparison of lung tissue concentrations of nebulized ceftazidime in ventilated piglets: ultrasonic versus vibrating plate nebulizers.

Authors:  Fabio Ferrari; Zhi-Hai Liu; Qin Lu; Marie-Helene Becquemin; Kamel Louchahi; Guy Aymard; Charles-Hugo Marquette; Jean-Jacques Rouby
Journal:  Intensive Care Med       Date:  2008-04-30       Impact factor: 17.440

Review 3.  Mechanical ventilation of the patient with severe chronic obstructive pulmonary disease.

Authors:  M T Gladwin; D J Pierson
Journal:  Intensive Care Med       Date:  1998-09       Impact factor: 17.440

4.  Initial observations of cell-mediated drug delivery to the deep lung.

Authors:  Arun Kumar; Mark Glaum; Nagwa El-Badri; Shyam Mohapatra; Edward Haller; Seungjoo Park; Leslie Patrick; Leigh Nattkemper; Dawn Vo; Don F Cameron
Journal:  Cell Transplant       Date:  2010-11-05       Impact factor: 4.064

Review 5.  Aerosolized diuretics for preterm infants with (or developing) chronic lung disease.

Authors:  L P Brion; R A Primhak; W Yong
Journal:  Cochrane Database Syst Rev       Date:  2006-07-19

6.  Effect of a spacer on pulmonary aerosol deposition from a jet nebuliser during mechanical ventilation.

Authors:  C J Harvey; M J O'Doherty; C J Page; S H Thomas; T O Nunan; D F Treacher
Journal:  Thorax       Date:  1995-01       Impact factor: 9.139

Review 7.  Fundamentals of aerosol therapy in critical care.

Authors:  Jayesh Dhanani; John F Fraser; Hak-Kim Chan; Jordi Rello; Jeremy Cohen; Jason A Roberts
Journal:  Crit Care       Date:  2016-10-07       Impact factor: 9.097

8.  Aerosol delivery with two ventilation modes during mechanical ventilation: a randomized study.

Authors:  Jonathan Dugernier; Gregory Reychler; Xavier Wittebole; Jean Roeseler; Virginie Depoortere; Thierry Sottiaux; Jean-Bernard Michotte; Rita Vanbever; Thierry Dugernier; Pierre Goffette; Marie-Agnes Docquier; Christian Raftopoulos; Philippe Hantson; François Jamar; Pierre-François Laterre
Journal:  Ann Intensive Care       Date:  2016-07-22       Impact factor: 6.925

9.  Heated air humidification versus cold air nebulization in newly tracheostomized patients.

Authors:  Richard Birk; Alexander Händel; Angela Wenzel; Benedikt Kramer; Christoph Aderhold; Karl Hörmann; Boris A Stuck; J Ulrich Sommer
Journal:  Head Neck       Date:  2017-10-09       Impact factor: 3.147

Review 10.  Aerosol delivery during invasive mechanical ventilation: a systematic review.

Authors:  Jonathan Dugernier; Stephan Ehrmann; Thierry Sottiaux; Jean Roeseler; Xavier Wittebole; Thierry Dugernier; François Jamar; Pierre-François Laterre; Gregory Reychler
Journal:  Crit Care       Date:  2017-10-21       Impact factor: 9.097

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.