Literature DB >> 8106241

137Cs internal contamination involving a Brazilian accident, and the efficacy of Prussian Blue treatment.

D R Melo1, J L Lipsztein, C A de Oliveira, L Bertelli.   

Abstract

In an accident involving the stealing and breaching of a radiotherapy source in Goiânia, Brazil, 39 individuals had a high level of 137Cs internal contamination. Prussian Blue was used, in doses that varied from 3-10 g d-1 for adults, to enhance the elimination of 137Cs from the body. The total internal committed doses and the effect of Prussian Blue treatment for 15 contaminated adults involved in this accident have been evaluated in this paper. Prussian Blue caused dose reductions in the range of 51-84%, with an average of 71%. This reduction was shown to be independent of the dosage of Prussian Blue. Total internal committed doses were in the range of 4.6 x 10(-3) Gy to 9.7 x 10(-1) Gy for the most-contaminated adults. Data on 137Cs biological half-lives for seven children contaminated in the accident are also presented.

Entities:  

Mesh:

Substances:

Year:  1994        PMID: 8106241     DOI: 10.1097/00004032-199403000-00002

Source DB:  PubMed          Journal:  Health Phys        ISSN: 0017-9078            Impact factor:   1.316


  7 in total

Review 1.  Risk Communication Strategies: Lessons Learned from Previous Disasters with a Focus on the Fukushima Radiation Accident.

Authors:  Erik R Svendsen; Ichiro Yamaguchi; Toshihide Tsuda; Jean Remy Davee Guimaraes; Martin Tondel
Journal:  Curr Environ Health Rep       Date:  2016-12

Review 2.  Metabolomic applications in radiation biodosimetry: exploring radiation effects through small molecules.

Authors:  Evan L Pannkuk; Albert J Fornace; Evagelia C Laiakis
Journal:  Int J Radiat Biol       Date:  2017-01-12       Impact factor: 2.694

3.  In vitro and in vivo evaluation of a novel ferrocyanide functionalized nanopourous silica decorporation agent for cesium in rats.

Authors:  Charles Timchalk; Jeffrey A Creim; Vichaya Sukwarotwat; Robert Wiacek; R Shane Addleman; Glen E Fryxell; Wassana Yantasee
Journal:  Health Phys       Date:  2010-09       Impact factor: 1.316

Review 4.  The role of mass spectrometry-based metabolomics in medical countermeasures against radiation.

Authors:  Andrew D Patterson; Christian Lanz; Frank J Gonzalez; Jeffrey R Idle
Journal:  Mass Spectrom Rev       Date:  2010 May-Jun       Impact factor: 10.946

5.  Preparation, Characterization, and In Vivo Pharmacoscintigraphy Evaluation of an Intestinal Release Delivery System of Prussian Blue for Decorporation of Cesium and Thallium.

Authors:  Nidhi Sandal; Gaurav Mittal; Aseem Bhatnagar; Dharam Pal Pathak; Ajay Kumar Singh
Journal:  J Drug Deliv       Date:  2017-11-29

6.  Serum Metabolomic Alterations Associated with Cesium-137 Internal Emitter Delivered in Various Dose Rates.

Authors:  Heng-Hong Li; Yun-Tien Lin; Evagelia C Laiakis; Maryam Goudarzi; Waylon Weber; Albert J Fornace
Journal:  Metabolites       Date:  2020-06-30

Review 7.  Eurados review of retrospective dosimetry techniques for internal exposures to ionising radiation and their applications.

Authors:  A Giussani; M A Lopez; H Romm; A Testa; E A Ainsbury; M Degteva; S Della Monaca; G Etherington; P Fattibene; I Güclu; A Jaworska; D C Lloyd; I Malátová; S McComish; D Melo; J Osko; A Rojo; S Roch-Lefevre; L Roy; E Shishkina; N Sotnik; S Y Tolmachev; A Wieser; C Woda; M Youngman
Journal:  Radiat Environ Biophys       Date:  2020-05-05       Impact factor: 1.925

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.