Microscopic air embolism during cerebral angiography and strategies for its avoidance.

H Markus1, A Loh, D Israel, T Buckenham, A Clifton, M M Brown.   

Abstract

Cerebral angiography is associated with a risk of neurological complications and air embolism may contribute towards this risk. To test this hypothesis, transcranial doppler ultrasonography was used to monitor the presence of air emboli in the middle cerebral arteries of 7 patients undergoing cerebral angiography. Doppler signals consistent with numerous air emboli were noted during each injection of radiographic contrast. This phenomenon was studied further in sheep. Radiographic contrast medium was injected into the carotid artery while a major carotid branch was insonated transorbitally. Embolic signals similar to those seen in patients were noted. Air was introduced at two points. First, at the time of drawing up the contrast into the syringe, especially with more viscous media. Standing the media before injection resulted in a highly significant reduction of air embolism, reducing the total mean duration of emboli from 1.32 (SD 0.60) s after immediate injection to 0.04 (0.05) s after ten minutes standing for iohexol 340 mg/mL (p < 0.001). Second, air was introduced at the time of injection, possibly by the formation of cavitation bubbles under pressure. This occurred most prominently with the less viscous contrast media and with saline, and was significantly reduced by slow injection (mean duration of emboli for saline 2.85 [2.43] s with fast injection compared with 0.32 [0.37] s with slow injection, p = 0.004). Air embolism may contribute towards neurological dysfunction after angiography. Measures should be taken to reduce this by allowing contrast media to stand prior to injection, and by flushing catheters with saline injected slowly.

Entities:  

Mesh:

Substances:

Year:  1993        PMID: 8096000     DOI: 10.1016/0140-6736(93)90561-t

Source DB:  PubMed          Journal:  Lancet        ISSN: 0140-6736            Impact factor:   79.321


  16 in total

1.  Quality improvement guidelines for adult diagnostic neuroangiography. Cooperative study between the ASNR, ASITN, and the SCVIR. American Society of Neuroradiology. American Society of Interventional and Therapeutic Neuroradiology. Society of Cardiovascular and Interventional Radiology.

Authors: 
Journal:  AJNR Am J Neuroradiol       Date:  2000-01       Impact factor: 3.825

Review 2.  [Proximal protection systems using carotid artery stent].

Authors:  I Q Grunwald; U Dorenbeck; C Axmann; C Roth; T Struffert; W Reith
Journal:  Radiologe       Date:  2004-10       Impact factor: 0.635

3.  In vitro observation of air bubbles during delivery of various detachable aneurysm embolization coils.

Authors:  Deok Hee Lee; Seon Moon Hwang; Ok Kyun Lim; Jae Kyun Kim
Journal:  Korean J Radiol       Date:  2012-06-18       Impact factor: 3.500

4.  The amount of solid cerebral microemboli during carotid stenting does not relate to the frequency of silent ischemic lesions.

Authors:  M Rosenkranz; J Fiehler; W Niesen; C Waiblinger; B Eckert; O Wittkugel; T Kucinski; J Röther; H Zeumer; C Weiller; U Sliwka
Journal:  AJNR Am J Neuroradiol       Date:  2006-01       Impact factor: 3.825

Review 5.  Targeting the brain: rationalizing the novel methods of drug delivery to the central nervous system.

Authors:  Shailendra Joshi; Eugene Ornstein; Jeffrey N Bruce
Journal:  Neurocrit Care       Date:  2007       Impact factor: 3.210

6.  Detection of microemboli by transcranial Doppler ultrasound.

Authors:  D G Grosset; D Georgiadis; A W Kelman; P Cowburn; S Stirling; K R Lees; A Faichney; A Mallinson; R Quin; I Bone; L Pettigrew; E Brodie; T MacKay; D J Wheatley
Journal:  Tex Heart Inst J       Date:  1996

7.  Silent microemboli related to diagnostic cerebral angiography: a matter of operator's experience and patient's disease.

Authors:  T Krings; K Willmes; R Becker; I G Meister; F J Hans; M H T Reinges; M Mull; A Thron
Journal:  Neuroradiology       Date:  2006-04-04       Impact factor: 2.804

8.  Cerebral microembolism during transcatheter closure of patent foramen ovale.

Authors:  J Ferrari; H Baumgartner; S Tentschert; V Dorda; W Lang; A Willfort-Ehringer; P Probst; W Lalouschek
Journal:  J Neurol       Date:  2004-07       Impact factor: 4.849

9.  Neurological deficits associated with the elastase-induced aneurysm model in rabbits.

Authors:  Liliana Cesar; Laszlo Miskolczi; Baruch B Lieber; Chander Sadasivan; Matthew J Gounis; Ajay K Wakhloo
Journal:  Neurol Res       Date:  2008-09-29       Impact factor: 2.448

10.  Symptomatic cerebral air embolism during neuro-angiographic procedures: incidence and problem avoidance.

Authors:  Rishi Gupta; Nirav Vora; Ajith Thomas; Donald Crammond; Ronald Roth; Tudor Jovin; Michael Horowitz
Journal:  Neurocrit Care       Date:  2007       Impact factor: 3.210

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.