Literature DB >> 8095940

Spiral CT evaluation of coronary artery bypass graft patency.

R Tello1, P Costello, C Ecker, G Hartnell.   

Abstract

Spiral CT (SCT) differs from conventional CT in that the entire heart can be rapidly imaged in the axial plane following the peripheral infusion of small quantities of contrast material. As contrast material travels through coronary artery bypass graft segments, good image detail is achieved, allowing visualization of entire coronary artery graft segments during a single injection. The patency of 43 coronary artery bypass grafts in 14 patients on contrast enhanced SCT, with timing tailored to patient-specific transit times, was compared with that obtained by selective graft angiography. With use of 5 or 8 mm/s table feed and 24 s volumetric acquisitions, SCT established graft patency with 85.7% sensitivity and 100% specificity compared to angiographic examination (96.4% sensitivity and 100% specificity). The mean time between angiography and SCT was 2.1 days, with 86% of SCT studies done within 24 h after angiography. The utilization of dynamic scanning to establish the patient-specific time delay prior to initiation of SCT proved crucial in improving the quality and reliability of SCT bypass graft patency assessment. The paired McNemar test indicates no significant difference between angiography and SCT in establishing patency rates.

Entities:  

Mesh:

Substances:

Year:  1993        PMID: 8095940     DOI: 10.1097/00004728-199303000-00014

Source DB:  PubMed          Journal:  J Comput Assist Tomogr        ISSN: 0363-8715            Impact factor:   1.826


  4 in total

Review 1.  Advances in cardiovascular CT imaging: CT clinical imaging.

Authors:  William Stanford
Journal:  Int J Cardiovasc Imaging       Date:  2005-02       Impact factor: 2.357

Review 2.  A practical approach to MRI of coronary artery bypass graft patency and flow.

Authors:  A C van Rossum; M A Galjee; J C Post; C A Visser
Journal:  Int J Card Imaging       Date:  1997-06

3.  Value of navigator echo magnetic resonance angiography in detecting occlusion/patency of arterial and venous, single and sequential coronary bypass grafts.

Authors:  G Molinari; F Sardanelli; F Zandrino; M Balbi; M A Masperone
Journal:  Int J Card Imaging       Date:  2000-06

Review 4.  CT for imaging coronary artery disease: defining the paradigm for its application.

Authors:  Bernd M Ohnesorge; Lars K Hofmann; Thomas G Flohr; U Joseph Schoepf
Journal:  Int J Cardiovasc Imaging       Date:  2005-02       Impact factor: 2.357

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.