Literature DB >> 8082670

Dobutamine 99mTc-MIBI single-photon emission tomography: non-exercise-dependent detection of haemodynamically significant coronary artery stenoses.

E Voth1, F M Baer, P Theissen, C A Schneider, U Sechtem, H Schicha.   

Abstract

Dobutamine pharmacological stress testing in conjunction with technetium-99m methoxyisobutylisonitrile single-photon emission tomography (MIBI SPET) may be a useful alternative to convential exercise stress MIBI SPET for the detection and localisation of coronary artery stenoses. Therefore, 35 patients with stenoses (> or = 50% diameter reduction) of one or more coronary arteries were selected for dobutamine MIBI SPET. Each patient underwent MIBI injection at rest and during dobutamine infusion with incremental doses (5, 10, 15 and 20 micrograms kg-1 min-1). A conventional exercise stress test (EST) was performed in all patients. Peak double product during steady-state dobutamine infusion (18,200 +/- 4200 mmHg min-1) was lower (P = 0.0001) than during EST (21,700 +/- 4900 mmHg min-1). Image quality was good in all but one patient, who had to be excluded from data analysis due to excessive hepatobiliary MIBI activity. Dobutamine-induced perfusion abnormalities were observed in 30/34 MIBI SPET studies, resulting in an overall detection rate for coronary artery disease of 88%. A pathological EST was observed in 23/34 patients (68%). The detection rate of individual coronary artery stenoses was 85% (28/33) for stenosess with a severe diameter reduction (> 70%) and 50% (12/24) for stenoses with a moderate diameter reduction (> or = 50-70%). In particular, sensitivity and specificity for the detection of moderate and severe stenoses (> or = 50%) were 75%/100% for left anterior descending, 67%/95% for left circumflex and 67%/69% for right coronary artery stenoses. Dobutamine MIBI SPET is a well-tolerated, non-exercise-dependent test for detection and localisation of haemodynamically significant coronary artery stenoses.(ABSTRACT TRUNCATED AT 250 WORDS)

Entities:  

Mesh:

Substances:

Year:  1994        PMID: 8082670     DOI: 10.1007/bf00173042

Source DB:  PubMed          Journal:  Eur J Nucl Med        ISSN: 0340-6997


  38 in total

1.  The localization of myocardial ischaemia with technetium-99m methoxy isobutyl isonitrile and single photon emission computed tomography.

Authors:  D J West; Y C Najm; R Mistry; S E Clarke; I Fogelman; M N Maisey
Journal:  Br J Radiol       Date:  1989-04       Impact factor: 3.039

2.  Gamma camera emission tomography. Development and properties of a multi-sectional emission computed tomography system.

Authors:  S A Larsson
Journal:  Acta Radiol Suppl       Date:  1980

3.  [99mTc-2-methoxy-isobutyl-isonitrile in the diagnosis of coronary heart disease: results of a multicenter study].

Authors:  H Höffken; K Joseph; C Alexander; R Bauer; R Berberich; A Bischof-Delaloye; I Böttger; H Botsch; U Büll; B Delaloye
Journal:  Nuklearmedizin       Date:  1990-08       Impact factor: 1.379

4.  A comparison of dobutamine infusion and supine bicycle exercise for radionuclide cardiac stress testing.

Authors:  M L Freeman; R Palac; J Mason; W E Barnes; G Eastman; S Virupannavar; H S Loeb; E Kaplan
Journal:  Clin Nucl Med       Date:  1984-05       Impact factor: 7.794

5.  Dobutamine thallium myocardial perfusion tomography.

Authors:  D J Pennell; S R Underwood; R H Swanton; J M Walker; P J Ell
Journal:  J Am Coll Cardiol       Date:  1991-11-15       Impact factor: 24.094

6.  Hemodynamic effects of dobutamine in patients following open heart surgery.

Authors:  T Sakamoto; T Yamada
Journal:  Circulation       Date:  1977-03       Impact factor: 29.690

7.  Identification of hemodynamically significant coronary artery stenoses by dipyridamole-magnetic resonance imaging and 99mTc-methoxyisobutyl-isonitrile-SPECT.

Authors:  F M Baer; K Smolarz; P Theissen; E Voth; H Schicha; U Sechtem
Journal:  Int J Card Imaging       Date:  1993-06

8.  Serial thallium-201 myocardial imaging after dipyridamole infusion: diagnostic utility in detecting coronary stenoses and relationship to regional wall motion.

Authors:  J Leppo; C A Boucher; R D Okada; J B Newell; H W Strauss; G M Pohost
Journal:  Circulation       Date:  1982-09       Impact factor: 29.690

Review 9.  Dipyridamole perfusion scintigraphy.

Authors:  E H Botvinick; M W Dae
Journal:  Semin Nucl Med       Date:  1991-07       Impact factor: 4.446

10.  Selection of the optimal nonexercise stress for the evaluation of ischemic regional myocardial dysfunction and malperfusion. Comparison of dobutamine and adenosine using echocardiography and 99mTc-MIBI single photon emission computed tomography.

Authors:  T Marwick; B Willemart; A M D'Hondt; T Baudhuin; W Wijns; J M Detry; J Melin
Journal:  Circulation       Date:  1993-02       Impact factor: 29.690

View more
  3 in total

Review 1.  Comparison of Tl-201 with Tc-99m-labeled myocardial perfusion agents: technical, physiologic, and clinical issues.

Authors:  P Kailasnath; A J Sinusas
Journal:  J Nucl Cardiol       Date:  2001 Jul-Aug       Impact factor: 5.952

Review 2.  What is the current status of quantification and nuclear medicine in cardiology?

Authors:  G Hör
Journal:  Eur J Nucl Med       Date:  1996-07

3.  Altered myocardial perfusion during dobutamine stress testing in silent versus symptomatic myocardial ischaemia assessed by quantitative MIBI SPET imaging.

Authors:  A Elhendy; M L Geleijnse; J R Roelandt; J H Cornel; R T van Domburg; A E Reijs; P R Nierop; P M Fioretti
Journal:  Eur J Nucl Med       Date:  1996-10
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.