Literature DB >> 2216808

[99mTc-2-methoxy-isobutyl-isonitrile in the diagnosis of coronary heart disease: results of a multicenter study].

H Höffken1, K Joseph, C Alexander, R Bauer, R Berberich, A Bischof-Delaloye, I Böttger, H Botsch, U Büll, B Delaloye.   

Abstract

A total of 226 patients was studied in a phase-III multicenter trial to compare the results of stress/rest 99mTc-MIBI with 201TI scintigraphy and/or coronary arteriography. The evaluation of planar and SPECT imaging was based on a semiquantitative visual scoring. A congruent diagnosis was generated from all planar 201TI and 99mTc-MIBI scintigrams performed in 36 patients. In 62 of 63 patients, SPECT-studies with 99mTc-MIBI and 201TI led to an identical diagnosis. In one patient a positive result was obtained with 201TI-SPECT whereas 99mTc-MIBI was negative. Segmental agreement for 1509 SPECT segments was 85.7%, for 554 planar segments it was 86.6%. In comparison to coronary arteriography, performed in 180 patients, the overall sensitivity for the correct diagnosis of coronary artery disease (CAD) was 86% for planar MIBI scintigraphy or 92% for MIBI-SPECT. Overall specificity was 100% for planar imaging and 57% for SPECT. The low specificity of MIBI-SPECT was probably due to high prevalence of CAD in this study population. In a subgroup of 43 patients, who underwent coronary angiography, identical results were found with 99mTc-MIBI and 201TI. Only one patient showed a positive scintigraphic result with both 99mTc-MIBI and 201TI without angiographically proven stenosis greater than 50% or prior myocardial infarction. Vessel sensitivities in stenosed coronary arteries (greater than 50% stenosis) were 54% for the LAD and 87% for the RCX/RCA areas with MIBI-SPECT, or 51% or 79% for planar scintigraphy, respectively. Vessel specificities for SPECT were 65% in the LAD or 52% in the RCX/RCA, or 90% or 83% in planar imaging.(ABSTRACT TRUNCATED AT 250 WORDS)

Entities:  

Mesh:

Substances:

Year:  1990        PMID: 2216808

Source DB:  PubMed          Journal:  Nuklearmedizin        ISSN: 0029-5566            Impact factor:   1.379


  3 in total

Review 1.  What is the current status of quantification and nuclear medicine in cardiology?

Authors:  G Hör
Journal:  Eur J Nucl Med       Date:  1996-07

2.  Identification of hemodynamically significant coronary artery stenoses by dipyridamole-magnetic resonance imaging and 99mTc-methoxyisobutyl-isonitrile-SPECT.

Authors:  F M Baer; K Smolarz; P Theissen; E Voth; H Schicha; U Sechtem
Journal:  Int J Card Imaging       Date:  1993-06

3.  Dobutamine 99mTc-MIBI single-photon emission tomography: non-exercise-dependent detection of haemodynamically significant coronary artery stenoses.

Authors:  E Voth; F M Baer; P Theissen; C A Schneider; U Sechtem; H Schicha
Journal:  Eur J Nucl Med       Date:  1994-06