Literature DB >> 8078044

Early failure of titanium alloy femoral components: a quantitative radiological analysis of osteolytic and granulomatous change.

A J Unwin1, P J Stiles.   

Abstract

Shot blasted titanium alloy femoral components with a coarse finish were withdrawn from use in 1987 following reports of early component failure. We reviewed all coarse titanium femoral stems used in primary total hip arthroplasty in our institution between 1985 and 1987 and compared them to a similar stem made of vitallium which was also used over the same period. We found that, at an average of 5.2 years following implantation, over two-thirds of titanium components were associated with endosteal lysis. In many of the cases the early lytic changes were asymptomatic with significant bone loss occurring prior to presentation. We discuss our findings in relation to revision surgery. We advocate that all those with coarse stem titanium components should be positively reviewed to detect early lytic change before extensive bone destruction occurs.

Entities:  

Mesh:

Substances:

Year:  1993        PMID: 8078044      PMCID: PMC1294051          DOI: 10.1177/014107689308600812

Source DB:  PubMed          Journal:  J R Soc Med        ISSN: 0141-0768            Impact factor:   18.000


  21 in total

1.  Metallosis associated with a stable titanium-alloy femoral component in total hip replacement. A case report.

Authors:  J Black; H Sherk; J Bonini; W R Rostoker; F Schajowicz; J O Galante
Journal:  J Bone Joint Surg Am       Date:  1990-01       Impact factor: 5.284

Review 2.  Femoral lysis after cemented hip arthroplasty.

Authors:  H D Huddleston
Journal:  J Arthroplasty       Date:  1988       Impact factor: 4.757

3.  Changes in nonosseous tissue adjacent to titanium implants.

Authors:  G Meachim; D F Williams
Journal:  J Biomed Mater Res       Date:  1973-11

4.  Reaction of bone to methacrylate after hip arthroplasty: a long-term gross, light microscopic, and scanning electron microscopic study.

Authors:  H G Willert; J Ludwig; M Semlitsch
Journal:  J Bone Joint Surg Am       Date:  1974-10       Impact factor: 5.284

5.  Sintered fiber metal composites as a basis for attachment of implants to bone.

Authors:  J Galante; W Rostoker; R Lueck; R D Ray
Journal:  J Bone Joint Surg Am       Date:  1971-01       Impact factor: 5.284

6.  Localized bone resorption in the femur in mechanical failure of cemented total hip arthroplasties.

Authors:  A S Carlsson; C F Gentz; L Linder
Journal:  Acta Orthop Scand       Date:  1983-06

7.  "Modes of failure" of cemented stem-type femoral components: a radiographic analysis of loosening.

Authors:  T A Gruen; G M McNeice; H C Amstutz
Journal:  Clin Orthop Relat Res       Date:  1979-06       Impact factor: 4.176

8.  Metallic wear in failed titanium-alloy total hip replacements. A histological and quantitative analysis.

Authors:  H J Agins; N W Alcock; M Bansal; E A Salvati; P D Wilson; P M Pellicci; P G Bullough
Journal:  J Bone Joint Surg Am       Date:  1988-03       Impact factor: 5.284

9.  The production and biology of polyethylene wear debris.

Authors:  P A Revell; B Weightman; M A Freeman; B V Roberts
Journal:  Arch Orthop Trauma Surg       Date:  1978-05-30

10.  Aggressive granulomatous lesions after hip arthroplasty.

Authors:  K Tallroth; A Eskola; S Santavirta; Y T Konttinen; T S Lindholm
Journal:  J Bone Joint Surg Br       Date:  1989-08
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.