Literature DB >> 8074091

In vitro torque-deformation characteristics of orthodontic polycarbonate brackets.

J C Feldner1, N K Sarkar, J J Sheridan, D M Lancaster.   

Abstract

The purpose of this study was to investigate the torque-deformation characteristics of the following four types of polycarbonate brackets: (1) pure polycarbonate, PPC (anterior Miura, RMO, Denver, Colo.), (2) ceramic reinforced polycarbonate, CRPC (Silkon bracket, American, Sheboygan, Wis.), (3) metal slot reinforced polycarbonate, MRPC (Plastic bracket, Tella Tech, Miami, Fla.), and (4) metal slot and ceramic reinforced polycarbonate, MCRPC (Spirit, Ormco, Glendora, Calif.). A stainless steel bracket, (Mini Diamond, Ormco, Glendora, Calif.), was used as a control. Ten brackets of each type were tested. Each bracket was bonded to a porcelain tooth and engaged in a torquemeter. The tooth-bracket assembly was made stationary by embedding it in die stone. Torsion was applied to the bracket at 4 degrees per minute and the resultant torque (grams.centimeters) and deformation (degree) were measured. For optimum labiolingual tooth movement for a maxillary incisor at 175 grams . centimeters, the amount of angular deflection necessary for the different polycarbonate brackets was the following: (a) 15 degrees for MRPC, (b) 17 degrees for MRPC, (c) 24 degrees for CRPC, and (d) > 30 degrees for PPC. The amount of deformation at this deflection was the least for MRCP followed by MCRPC, CRCP, and PPC. When compared with the stainless steel bracket, all polycarbonate brackets showed significantly (p < 0.0001) higher deformation and lower torque. Within the polycarbonate group, there was a significant difference (p < 0.0001) between each bracket for both measurements. The MRPC produced the highest torque and lowest deformation values followed by the MCRPC, CRCP, and PPC. It appears that only the metal slot reinforced brackets are clinically capable of torquing teeth sufficiently.

Entities:  

Mesh:

Substances:

Year:  1994        PMID: 8074091     DOI: 10.1016/S0889-5406(94)70046-X

Source DB:  PubMed          Journal:  Am J Orthod Dentofacial Orthop        ISSN: 0889-5406            Impact factor:   2.650


  11 in total

1.  Shear bond strength of an experimental composite bracket.

Authors:  Zhe-chen Zhang; Russell Giordano; Gang Shen; L Lee Chou; Yu-fen Qian
Journal:  J Orofac Orthop       Date:  2013-06-28       Impact factor: 1.938

2.  Torque stability of plastic brackets following multiple loading and artificial material aging--an in-vitro comparison.

Authors:  Matthias Möller; Arndt Klocke; Reza Sadat-Khonsari; Volker Schlegel; Bärbel Kahl-Nieke
Journal:  J Orofac Orthop       Date:  2009-12-09       Impact factor: 1.938

3.  Survey on awareness and preference of ceramic bracket debonding techniques among orthodontists.

Authors:  Aileen Y Ngan; Prashanti Bollu; Kishore Chaudhry; Richard Stevens; Karthikeyan Subramani
Journal:  J Clin Exp Dent       Date:  2020-07-01

4.  Active and passive self-ligation: a myth? Part 1: torque control.

Authors:  Lorenz Martin Brauchli; Markus Steineck; Andrea Wichelhaus
Journal:  Angle Orthod       Date:  2011-11-07       Impact factor: 2.079

Review 5.  Torque expression in stainless steel orthodontic brackets. A systematic review.

Authors:  Amy Archambault; Ryan Lacoursiere; Hisham Badawi; Paul W Major; Jason Carey; Carlos Flores-Mir
Journal:  Angle Orthod       Date:  2010-01       Impact factor: 2.079

6.  Torsional superelasticity of NiTi archwires.

Authors:  Yves Bolender; Anne Vernière; Christophe Rapin; Marie-Pierryle Filleul
Journal:  Angle Orthod       Date:  2010-11       Impact factor: 2.079

7.  Labio-lingual root control of lower anterior teeth and canines obtained by active and passive self-ligating brackets.

Authors:  Paolo M Cattaneo; Raaid A Salih; Birte Melsen
Journal:  Angle Orthod       Date:  2012-12-18       Impact factor: 2.079

8.  Evaluation of mechanical properties of esthetic brackets.

Authors:  Shigeyuki Matsui; Eisaku Umezaki; Daigo Komazawa; Yuichiro Otsuka; Naoto Suda
Journal:  J Dent Biomech       Date:  2015-02-26

9.  Three-dimensional deformation of orthodontic brackets.

Authors:  Garrett W Melenka; David S Nobes; Paul W Major; Jason P Carey
Journal:  J Dent Biomech       Date:  2013-06-06

10.  In vitro physical, chemical, and biological evaluation of commercially available metal orthodontic brackets.

Authors:  Joo Hyoung Kim; Jung Yul Cha; Chung Ju Hwang
Journal:  Korean J Orthod       Date:  2012-12-28       Impact factor: 1.372

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.