Congenital methaemoglobinaemia detected by preoperative pulse oximetry.

D G Chisholm1, H Stuart.   

Abstract

Methaemoglobinaemia is an unusual cause of cyanosis whether it is congenital or acquired. Hence, the diagnosis may not be immediately obvious and appropriate treatment may be delayed. The case described shows that it should be considered when pulse oximetry and arterial blood gas analysis appear to give conflicting results. A healthy 24-yr-old woman was found to have a pulse oximeter reading of 82% prior to induction of anaesthesia for minor surgery. Clinical examination confirmed cyanosis but no other abnormality was detected. She had no important medical history and was not receiving any medications. Arterial blood gas analysis with the patient breathing air showed PaO2 12.03 kPa (90 mmHg). Co-oximeter analysis of this sample revealed a methaemoglobin content of 13.4% and she was subsequently found to have congenital methaemoglobin reductase deficiency. Anaesthesia was induced and maintained with incremental doses of propofol and fentanyl. A spontaneously breathing technique with oxygen in nitrous oxide was employed uneventfully. No specific treatment for methaemoglobinaemia was given. Perioperative pulse oximetry is one of the major advances in patient monitoring in recent years but unexpected results should not be accepted uncritically. A knowledge of the working principles of oximetry is essential to enable appropriate management in the presence of dyshaemoglobins.

Entities:  

Mesh:

Substances:

Year:  1994        PMID: 8069994     DOI: 10.1007/BF03011548

Source DB:  PubMed          Journal:  Can J Anaesth        ISSN: 0832-610X            Impact factor:   5.063


  10 in total

Review 1.  Potential errors in pulse oximetry. I. Pulse oximeter evaluation.

Authors:  A C Ralston; R K Webb; W B Runciman
Journal:  Anaesthesia       Date:  1991-03       Impact factor: 6.955

2.  Spurious pulse oximetry with intrauterine methylene blue injection.

Authors:  D M Scott; M G Cooper
Journal:  Anaesth Intensive Care       Date:  1991-05       Impact factor: 1.669

3.  Methemoglobinemia and sulfhemoglobinemia.

Authors:  C A FINCH
Journal:  N Engl J Med       Date:  1948-09-23       Impact factor: 91.245

4.  Inverse relationship between age-dependent erythrocyte activity of methaemoglobin reductase and prilocaine-induced methaemoglobinaemia during infancy.

Authors:  A Nilsson; G Engberg; S Henneberg; K Danielson; C H De Verdier
Journal:  Br J Anaesth       Date:  1990-01       Impact factor: 9.166

5.  Effects of methemoglobinemia on pulse oximetry and mixed venous oximetry.

Authors:  S J Barker; K K Tremper; J Hyatt
Journal:  Anesthesiology       Date:  1989-01       Impact factor: 7.892

6.  Catalysis of methaemoglobin reduction by erythrocyte cytochrome B5 and cytochrome B5 reductase.

Authors:  D E Hultquist; P G Passon
Journal:  Nat New Biol       Date:  1971-02-24

7.  The generation of superoxide radical during the autoxidation of hemoglobin.

Authors:  H P Misra; I Fridovich
Journal:  J Biol Chem       Date:  1972-11-10       Impact factor: 5.157

8.  Methemoglobinemia provoked by malarial chemoprophylaxis in Vietnam.

Authors:  R J Cohen; J R Sachs; D J Wicker; M E Conrad
Journal:  N Engl J Med       Date:  1968-11-21       Impact factor: 91.245

9.  Comparison of recorded values from six pulse oximeters.

Authors:  H Choe; C Tashiro; K Fukumitsu; M Yagi; I Yoshiya
Journal:  Crit Care Med       Date:  1989-07       Impact factor: 7.598

Review 10.  Potential errors in pulse oximetry. II. Effects of changes in saturation and signal quality.

Authors:  R K Webb; A C Ralston; W B Runciman
Journal:  Anaesthesia       Date:  1991-03       Impact factor: 6.955

  10 in total
  2 in total

1.  NADH-diaphorase deficiency identified in a patient with congenital methaemoglobinaemia detected by pulse oximetry.

Authors:  K Sugahara; T Sadohara; T Kawaguchi; T Hirano
Journal:  Intensive Care Med       Date:  1998-07       Impact factor: 17.440

2.  Haemoglobin Hammersmith precludes monitoring with conventional pulse oximetry.

Authors:  S A Lang; P C Chang; V A Laxdal; T H Huisman
Journal:  Can J Anaesth       Date:  1994-10       Impact factor: 5.063

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.