Literature DB >> 8068520

Spin-echo and gradient-echo EPI of human brain activation using BOLD contrast: a comparative study at 1.5 T.

P A Bandettini1, E C Wong, A Jesmanowicz, R S Hinks, J S Hyde.   

Abstract

In this study, Blood Oxygenation Level Dependent (BOLD) contrast in the detection of human brain activation was compared between spin-echo and gradient-echo echo-planar sequences at 1.5 T. Time course series of spin-echo and gradient-echo images containing the primary motor cortex were collected during rest (no finger movement) and activation (finger movement). Each time course series was collected using a different TE. Resting and active state signal intensities at each TE were measured in identical regions in the motor cortex. From these data, resting and active state R2 (1/T2) and R2* (1/T2*) values were obtained. Across four subjects, brain activation produced an average R2 change of -0.16 +/- 0.02/s (+/- SE), and an average R2* change of -0.55 +/- 0.08/s. The average delta R2*/delta R2 ratio was 3.52 +/- 0.56. The average gradient-echo/spin-echo ratio of activation-induced signal changes at the TE for maximal BOLD contrast for each sequence (TE approximately T2* and T2) was calculated to be 1.87 +/- 0.40.

Entities:  

Mesh:

Substances:

Year:  1994        PMID: 8068520     DOI: 10.1002/nbm.1940070104

Source DB:  PubMed          Journal:  NMR Biomed        ISSN: 0952-3480            Impact factor:   4.044


  61 in total

1.  Use of spin echo T(2) BOLD in assessment of cerebral misery perfusion at 1.5 T.

Authors:  M Kavec; O H Gröhn; M I Kettunen; M J Silvennoinen; M Penttonen; R A Kauppinen
Journal:  MAGMA       Date:  2001-03       Impact factor: 2.310

2.  Distinct neural substrates for semantic knowledge and naming in the temporoparietal network.

Authors:  Benno Gesierich; Jorge Jovicich; Marianna Riello; Michela Adriani; Alessia Monti; Valentina Brentari; Simon D Robinson; Stephen M Wilson; Scott L Fairhall; Maria Luisa Gorno-Tempini
Journal:  Cereb Cortex       Date:  2011-11-02       Impact factor: 5.357

3.  Temporal resolving power of spin echo and gradient echo fMRI at 3T with apparent diffusion coefficient compartmentalization.

Authors:  Justin Hulvershorn; Luke Bloy; Eugene E Gualtieri; Christopher P Redmann; John S Leigh; Mark A Elliott
Journal:  Hum Brain Mapp       Date:  2005-06       Impact factor: 5.038

Review 4.  Magnetic resonance imaging of neuronal function in the spinal cord: spinal FMRI.

Authors:  Patrick W Stroman
Journal:  Clin Med Res       Date:  2005-08

5.  A pulse sequence for rapid in vivo spin-locked MRI.

Authors:  Arijitt Borthakur; Justin Hulvershorn; Eugene Gualtieri; Andrew J Wheaton; Sridhar Charagundla; Mark A Elliott; Ravinder Reddy
Journal:  J Magn Reson Imaging       Date:  2006-04       Impact factor: 4.813

6.  Age-dependent normal values of T2* and T2' in brain parenchyma.

Authors:  S Siemonsen; J Finsterbusch; J Matschke; A Lorenzen; X-Q Ding; J Fiehler
Journal:  AJNR Am J Neuroradiol       Date:  2008-02-13       Impact factor: 3.825

7.  More than BOLD: Dual-spin populations create functional contrast.

Authors:  Amanda J Taylor; Jung H Kim; Vimal Singh; Elizabeth J Halfen; Josef Pfeuffer; David Ress
Journal:  Magn Reson Med       Date:  2019-08-18       Impact factor: 4.668

8.  Echo time dependence of BOLD fMRI studies of the piriform cortex.

Authors:  Rainer Kopietz; Jessica Albrecht; Jennifer Linn; Olga Pollatos; Andrea Anzinger; Tim Wesemann; Gunther Fesl; Thomas Stephan; Hartmut Brückmann; Martin Wiesmann
Journal:  Klin Neuroradiol       Date:  2009-11-21

9.  Oxygen metabolism in ischemic stroke using magnetic resonance imaging.

Authors:  Hongyu An; Qingwei Liu; Yasheng Chen; Katie D Vo; Andria L Ford; Jin-Moo Lee; Weili Lin
Journal:  Transl Stroke Res       Date:  2011-12-13       Impact factor: 6.829

10.  3D in utero quantification of T2* relaxation times in human fetal brain tissues for age optimized structural and functional MRI.

Authors:  Anna I Blazejewska; Sharmishtaa Seshamani; Susan K McKown; Jason S Caucutt; Manjiri Dighe; Christopher Gatenby; Colin Studholme
Journal:  Magn Reson Med       Date:  2016-10-03       Impact factor: 4.668

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.