Literature DB >> 8067535

Novel, reagentless, amperometric biosensor for uric acid based on a chemically modified screen-printed carbon electrode coated with cellulose acetate and uricase.

M A Gilmartin1, J P Hart.   

Abstract

Amperometry in stirred solution has been used for the systematic evaluation of modified screen-printed carbon electrodes (SPCEs) with a view to developing a reagentless biosensor for uric acid. The developed system consists of a base cobalt phthalocyanine (CoPC) electrode tailored to the electrocatalytic oxidation of H2O2 by means of a cellulose acetate (CA)-uricase bilayer. Uricase was immobilized by drop-coating the enzyme onto the CA membrane covering the CoPC-SPCE. The device exploits the near-universal H2O2-generating propensity of oxidases, the permselectivity of the CA film towards H2O2 and the electrocatalytic oxidation of this product at the CoPC-SPCE. The electrochemical oxidation of the resulting Co+ species was used as the analytical signal, facilitating the application of a greatly reduced operating potential when compared with that required for direct oxidation of H2O2 at unmodified electrodes. The time required to achieve 95% of the steady-state current (t95i(ss)) was 44 s [relative standard deviation = 7.5% (n = 10)]. Amperometric calibrations were linear over the range from 13 x 10(-6) to 1 x 10(-3) mol dm-3, with the former representing the limit of detection. The CA membrane extended the linear range of the biosensor by over two orders of magnitude, when apparent Michaelis-Menten constants (Km') of immobilized and free enzymes are compared. This suggests that the process is diffusion-controlled and not governed by the kinetics of the enzyme. The precision of electrode fabrication was determined by cyclic voltammetry to be 4.9% (n = 6).(ABSTRACT TRUNCATED AT 250 WORDS)

Entities:  

Mesh:

Substances:

Year:  1994        PMID: 8067535     DOI: 10.1039/an9941900833

Source DB:  PubMed          Journal:  Analyst        ISSN: 0003-2654            Impact factor:   4.616


  5 in total

1.  Head-to-head comparisons of carbon fiber microelectrode coatings for sensitive and selective neurotransmitter detection by voltammetry.

Authors:  Yogesh S Singh; Lauren E Sawarynski; Pasha D Dabiri; Wonwoo R Choi; Anne M Andrews
Journal:  Anal Chem       Date:  2011-08-03       Impact factor: 6.986

2.  Construction of uricase-overproducing strains of Hansenula polymorpha and its application as biological recognition element in microbial urate biosensor.

Authors:  Kostyantyn V Dmytruk; Oleh V Smutok; Olena V Dmytruk; Wolfgang Schuhmann; Andriy A Sibirny
Journal:  BMC Biotechnol       Date:  2011-05-25       Impact factor: 2.563

Review 3.  Screen-Printed Voltammetric Sensors-Tools for Environmental Water Monitoring of Painkillers.

Authors:  Katarzyna Tyszczuk-Rotko; Jędrzej Kozak; Bożena Czech
Journal:  Sensors (Basel)       Date:  2022-03-22       Impact factor: 3.576

Review 4.  Recent Advances in Cellulose-Based Biosensors for Medical Diagnosis.

Authors:  Samir Kamel; Tawfik A Khattab
Journal:  Biosensors (Basel)       Date:  2020-06-17

5.  Voltammetric determination of acetaminophen in pharmaceutical preparations and human urine using glassy carbon paste electrode modified with reduced graphene oxide.

Authors:  Amir Shaaban Farag
Journal:  Anal Sci       Date:  2022-07-09       Impact factor: 1.967

  5 in total