Literature DB >> 21770471

Head-to-head comparisons of carbon fiber microelectrode coatings for sensitive and selective neurotransmitter detection by voltammetry.

Yogesh S Singh1, Lauren E Sawarynski, Pasha D Dabiri, Wonwoo R Choi, Anne M Andrews.   

Abstract

Voltammetry is widely used to investigate neurotransmission and other biological processes but is limited by poor chemical selectivity and fouling of commonly used carbon fiber microelectrodes (CFMs). We performed direct comparisons of three key coating materials purported to impart selectivity and fouling resistance to electrodes: Nafion, base-hydrolyzed cellulose acetate (BCA), and fibronectin. We systematically evaluated the impact on a range of electrode parameters. Fouling due to exposure to brain tissue was investigated using an approach that minimizes the use of animals while enabling evaluation of statistically significant populations of electrodes. We find that BCA is relatively fouling-resistant. Moreover, detection at BCA-coated CFMs can be tuned by altering hydrolysis times to minimize the impact on sensitivity losses while maintaining fouling resistance. Fibronectin coating is associated with moderate losses in sensitivity after coating and fouling. Nafion imparts increased sensitivity for dopamine and norepinephrine but not serotonin, as well as the anticipated selectivity for cationic neurotransmitters over anionic metabolites. Although Nafion has been suggested to resist fouling, both dip-coating and electrodeposition of Nafion are associated with substantial fouling, similar to levels observed at bare electrodes after exposure to brain tissue. Direct comparisons of these coatings identified unique electroanalytical properties of each that can be used to guide selection tailored to the goals and environment of specific studies.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21770471      PMCID: PMC3165139          DOI: 10.1021/ac2011729

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  72 in total

Review 1.  Characterization of implantable biosensor membrane biofouling.

Authors:  N Wisniewski; F Moussy; W M Reichert
Journal:  Fresenius J Anal Chem       Date:  2000 Mar-Apr

2.  Subsecond detection of physiological adenosine concentrations using fast-scan cyclic voltammetry.

Authors:  B E Kumara Swamy; B Jill Venton
Journal:  Anal Chem       Date:  2007-01-15       Impact factor: 6.986

3.  Measurement of nanomolar dopamine diffusion using low-noise perfluorinated ionomer coated carbon fiber microelectrodes and high-speed cyclic voltammetry.

Authors:  M E Rice; C Nicholson
Journal:  Anal Chem       Date:  1989-09-01       Impact factor: 6.986

4.  Mechanisms contributing to the recovery of striatal releasable dopamine following MFB stimulation.

Authors:  A C Michael; M Ikeda; J B Justice
Journal:  Brain Res       Date:  1987-09-22       Impact factor: 3.252

5.  Voltammetric study of extracellular dopamine near microdialysis probes acutely implanted in the striatum of the anesthetized rat.

Authors:  Laura M Borland; Guoyue Shi; Hua Yang; Adrian C Michael
Journal:  J Neurosci Methods       Date:  2005-03-05       Impact factor: 2.390

6.  Voltammetric characterization of the effect of monoamine uptake inhibitors and releasers on dopamine and serotonin uptake in mouse caudate-putamen and substantia nigra slices.

Authors:  Carrie E John; Sara R Jones
Journal:  Neuropharmacology       Date:  2007-03-16       Impact factor: 5.250

7.  Regional differences in extracellular ascorbic acid levels in the rat brain determined by high speed cyclic voltammetry.

Authors:  J A Stamford; Z L Kruk; J Millar
Journal:  Brain Res       Date:  1984-05-14       Impact factor: 3.252

8.  Real-time glutamate measurements in the putamen of awake rhesus monkeys using an enzyme-based human microelectrode array prototype.

Authors:  Michelle L Stephens; Francois Pomerleau; Peter Huettl; Greg A Gerhardt; Zhiming Zhang
Journal:  J Neurosci Methods       Date:  2009-10-20       Impact factor: 2.390

9.  Voltammetric detection of 5-hydroxytryptamine release in the rat brain.

Authors:  Parastoo Hashemi; Elyse C Dankoski; Jelena Petrovic; Richard B Keithley; R M Wightman
Journal:  Anal Chem       Date:  2009-11-15       Impact factor: 6.986

10.  Chronic microsensors for longitudinal, subsecond dopamine detection in behaving animals.

Authors:  Jeremy J Clark; Stefan G Sandberg; Matthew J Wanat; Jerylin O Gan; Eric A Horne; Andrew S Hart; Christina A Akers; Jones G Parker; Ingo Willuhn; Vicente Martinez; Scott B Evans; Nephi Stella; Paul E M Phillips
Journal:  Nat Methods       Date:  2009-12-27       Impact factor: 28.547

View more
  26 in total

1.  Context-dependent fluctuation of serotonin in the auditory midbrain: the influence of sex, reproductive state and experience.

Authors:  Jessica L Hanson; Laura M Hurley
Journal:  J Exp Biol       Date:  2013-11-06       Impact factor: 3.312

2.  Computational Modeling of Neurotransmitter Release Evoked by Electrical Stimulation: Nonlinear Approaches to Predicting Stimulation-Evoked Dopamine Release.

Authors:  James K Trevathan; Ali Yousefi; Hyung Ook Park; John J Bartoletta; Kip A Ludwig; Kendall H Lee; J Luis Lujan
Journal:  ACS Chem Neurosci       Date:  2017-02-06       Impact factor: 4.418

3.  A Materials Roadmap to Functional Neural Interface Design.

Authors:  Steven M Wellman; James R Eles; Kip A Ludwig; John P Seymour; Nicholas J Michelson; William E McFadden; Alberto L Vazquez; Takashi D Y Kozai
Journal:  Adv Funct Mater       Date:  2017-07-19       Impact factor: 18.808

4.  O2 Plasma Etching and Antistatic Gun Surface Modifications for CNT Yarn Microelectrode Improve Sensitivity and Antifouling Properties.

Authors:  Cheng Yang; Ying Wang; Christopher B Jacobs; Ilia N Ivanov; B Jill Venton
Journal:  Anal Chem       Date:  2017-04-28       Impact factor: 6.986

Review 5.  Fundamentals of fast-scan cyclic voltammetry for dopamine detection.

Authors:  B Jill Venton; Qun Cao
Journal:  Analyst       Date:  2020-02-17       Impact factor: 4.616

6.  3D-printed CuO nanoparticle-functionalized flow reactor enables online fluorometric monitoring of glucose.

Authors:  Cheng-Kuan Su; Hsin-Heng Tseng
Journal:  Mikrochim Acta       Date:  2019-06-10       Impact factor: 5.833

7.  Sampling phasic dopamine signaling with fast-scan cyclic voltammetry in awake, behaving rats.

Authors:  S M Fortin; J J Cone; S Ng-Evans; J E McCutcheon; M F Roitman
Journal:  Curr Protoc Neurosci       Date:  2015-01-05

8.  Electrochemical treatment in KOH renews and activates carbon fiber microelectrode surfaces.

Authors:  Qun Cao; Julia Lucktong; Zijun Shao; Yuanyu Chang; B Jill Venton
Journal:  Anal Bioanal Chem       Date:  2021-07-23       Impact factor: 4.142

9.  Unmasking the Effects of L-DOPA on Rapid Dopamine Signaling with an Improved Approach for Nafion Coating Carbon-Fiber Microelectrodes.

Authors:  Lingjiao Qi; Elina Thomas; Stephanie H White; Samantha K Smith; Christie A Lee; Leslie R Wilson; Leslie A Sombers
Journal:  Anal Chem       Date:  2016-08-03       Impact factor: 6.986

10.  Electrochemical nanoprobes for the chemical detection of neurotransmitters.

Authors:  Mei Shen; Michelle L Colombo
Journal:  Anal Methods       Date:  2015-09-07       Impact factor: 2.896

View more