Literature DB >> 8062860

A 5-year clinical review of bond failure with a no-mix adhesive (Right on).

D T Millett1, P H Gordon.   

Abstract

The performance of 5941 stainless steel orthodontic brackets bonded with a no-mix adhesive (Right-on) in 563 patients was reviewed over a 5-year period. The effects of age and sex of the patient, treatment mechanics, operator experience, and arch location on the failure rate and mean survival time (MST) of bonded orthodontic brackets were examined. The overall failure rate was 8 per cent (MST 45.7 months). The failure rate of brackets was three times greater in patients aged less than 12 years at the start of treatment compared with those aged greater than 16 years at the start of treatment. The MST was significantly different between male and female patients. Brackets bonded in patients treated with Begg mechanics had a greater failure rate than those bonded in patients treated with other appliance mechanics. The failure rates and MST of brackets were significantly affected by all the variables examined.

Entities:  

Mesh:

Substances:

Year:  1994        PMID: 8062860     DOI: 10.1093/ejo/16.3.203

Source DB:  PubMed          Journal:  Eur J Orthod        ISSN: 0141-5387            Impact factor:   3.075


  8 in total

1.  Failure patterns of different bracket systems and their influence on treatment duration: A retrospective cohort study.

Authors:  Dimitrios Stasinopoulos; Spyridon N Papageorgiou; Frank Kirsch; Nikolaos Daratsianos; Andreas Jäger; Christoph Bourauel
Journal:  Angle Orthod       Date:  2018-02-02       Impact factor: 2.079

2.  Characterization of the porosity of human dental enamel and shear bond strength in vitro after variable etch times: initial findings using the BET method.

Authors:  Trang T Nguyen; Arthur Miller; Maria F Orellana
Journal:  Angle Orthod       Date:  2011-02-21       Impact factor: 2.079

Review 3.  Adhesives for bonded molar tubes during fixed brace treatment.

Authors:  Declan T Millett; Nicky A Mandall; Rye Cr Mattick; Joy Hickman; Anne-Marie Glenny
Journal:  Cochrane Database Syst Rev       Date:  2017-02-23

Review 4.  Slow-release fluoride devices for the control of dental decay.

Authors:  Lee-Yee Chong; Jan E Clarkson; Lorna Dobbyn-Ross; Smriti Bhakta
Journal:  Cochrane Database Syst Rev       Date:  2018-03-01

5.  A 15-month evaluation of bond failures of orthodontic brackets bonded with direct versus indirect bonding technique: a clinical trial.

Authors:  Anna Menini; Mauro Cozzani; Maria Francesca Sfondrini; Andrea Scribante; Paolo Cozzani; Paola Gandini
Journal:  Prog Orthod       Date:  2014-12-30       Impact factor: 2.750

6.  In vitro evaluation of shear bond strength of orthodontic stainless steel brackets using transillumination.

Authors:  Keith R Dobrin; Prashanti Bollu; Kishore Chaudhry; Karthikeyan Subramani
Journal:  J Clin Exp Dent       Date:  2018-05-01

7.  The effect of pre-cure bracket movement on shear bond strength during placement of orthodontic brackets, an in vitro study.

Authors:  Byron Tam; Prashanti Bollu; Kishore Chaudhry; Karthikeyan Subramani
Journal:  J Clin Exp Dent       Date:  2017-10-01

8.  Survival analysis of brackets and tubes: A twelve-month assessment.

Authors:  Min-Ho Jung
Journal:  Angle Orthod       Date:  2014-03-25       Impact factor: 2.079

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.