Literature DB >> 8062525

Detection of changes in intrathoracic fluid in man using electrical impedance tomography.

J H Campbell1, N D Harris, F Zhang, A H Morice, B H Brown.   

Abstract

1. The Sheffield electrical impedance tomography system produces information on changes in the distribution of resistivity within tissue. We report on the assessment of electrical impedance tomography in monitoring changes in lung resistivity during a fluid challenge in normal man. 2. Eight normal subjects were studied. Electrical impedance tomography recordings were made at three different lung volumes before, during and after the intravenous infusion of 1 litre of 0.9% NaCl (saline). 3. The mean fall in lung resistivity during the infusion was -22% at total lung capacity (range -10% to -28%), -24% at tidal breathing (-15% to -37%) and -11% at residual volume (-5% to -19%) (P < 0.05 mean pre-infusion resistivity compared with the nadir value after infusion, Wilcoxon). 4. These changes in lung resistivity were probably due to a combination of a fall in haematocrit and an expansion of pulmonary blood volume.

Entities:  

Mesh:

Substances:

Year:  1994        PMID: 8062525     DOI: 10.1042/cs0870097

Source DB:  PubMed          Journal:  Clin Sci (Lond)        ISSN: 0143-5221            Impact factor:   6.124


  5 in total

1.  Model for the dielectric properties of human lung tissue against frequency and air content.

Authors:  P Nopp; N D Harris; T X Zhao; B H Brown
Journal:  Med Biol Eng Comput       Date:  1997-11       Impact factor: 2.602

2.  Prediction of cardiogenic pulmonary edema onset by monitoring right lung impedance.

Authors:  Michael Shochat; Gideon Charach; Shmuel Meyler; Simcha Meisel; Moshe Weintraub; Galina Mengeritsky; Morris Mosseri; Pavel Rabinovich
Journal:  Intensive Care Med       Date:  2006-06-15       Impact factor: 17.440

3.  Preventive treatment of alveolar pulmonary edema of cardiogenic origin.

Authors:  Gideon Charach; Michael Shochat; Alexander Rabinovich; Oded Ayzenberg; Jacob George; Lior Charach; Pavel Rabinovich
Journal:  J Geriatr Cardiol       Date:  2012-12       Impact factor: 3.327

4.  Internal thoracic impedance - a useful method for expedient detection and convenient monitoring of pleural effusion.

Authors:  Gideon Charach; Olga Rubalsky; Lior Charach; Alexander Rabinovich; Ori Argov; Ori Rogowski; Jacob George
Journal:  PLoS One       Date:  2015-04-28       Impact factor: 3.240

5.  Real-Time Detection of Hemothorax and Monitoring its Progression in a Piglet Model by Electrical Impedance Tomography: A Feasibility Study.

Authors:  Lin Yang; Chao Zhang; Wenbo Liu; Hang Wang; Junying Xia; Benyuan Liu; Xuetao Shi; Xiuzhen Dong; Feng Fu; Meng Dai
Journal:  Biomed Res Int       Date:  2020-02-27       Impact factor: 3.411

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.