Literature DB >> 8057812

Microscopic susceptibility variation and transverse relaxation: theory and experiment.

R M Weisskoff1, C S Zuo, J L Boxerman, B R Rosen.   

Abstract

Microscopic susceptibility variations invariably increase apparent transverse relaxation rates. In this paper, we present comparisons between Monte Carlo simulations and experiments with polystyrene microspheres to demonstrate that this enhanced relaxation can be explained quantitatively for both spin echo and gradient echo imaging experiments. The spheres used (1 to 30 microms), and degree of susceptibility variation (caused by 0-12 mM Dy-DTPA) covered a wide range of biologically relevant compartment sizes and contrast agent concentrations. These results show that several regimes of behavior exist, and that contrast dependence is quite different in these regimes. For a given susceptibility, delta chi, a small range of particle sizes show peak transverse relaxation. For the range of susceptibilities found in the first pass of a clinical IV contrast agent bolus, this size range is 5 to 10 microns, or roughly capillary sized compartments. In both our simulations and experiments, smaller spheres showed quadratic relaxation versus concentration curves, and larger particles showed sublinear behavior. For particles corresponding to the peak relaxivity, the relaxation-concentration curves were linear. In addition, we demonstrated that increasing the diffusion coefficient can increase, decrease, or, paradoxically, leave unaffected the apparent relaxation rate. The regime for which the diffusion coefficient is relatively unimportant corresponds to the region of peak relaxivity. By using the Bloch-Torrey equation to produce scaling rules, the specific Monte Carlo simulations were extended to more general cases. We use these scaling rules to demonstrate why we often find that susceptibility-induced relaxation rates vary approximately linearly with concentration of injected agent.

Entities:  

Mesh:

Substances:

Year:  1994        PMID: 8057812     DOI: 10.1002/mrm.1910310605

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  130 in total

1.  MR blood oxygenation level-dependent signal differences in parenchymal and large draining vessels: implications for functional MR imaging.

Authors:  T Krings; S G Erberich; F Roessler; J Reul; A Thron
Journal:  AJNR Am J Neuroradiol       Date:  1999 Nov-Dec       Impact factor: 3.825

2.  Reproducibility of BOLD-based functional MRI obtained at 4 T.

Authors:  C Tegeler; S C Strother; J R Anderson; S G Kim
Journal:  Hum Brain Mapp       Date:  1999       Impact factor: 5.038

Review 3.  Functional mapping in the human brain using high magnetic fields.

Authors:  K Uğurbil; X Hu; W Chen; X H Zhu; S G Kim; A Georgopoulos
Journal:  Philos Trans R Soc Lond B Biol Sci       Date:  1999-07-29       Impact factor: 6.237

Review 4.  Functional magnetic resonance imaging: imaging techniques and contrast mechanisms.

Authors:  A M Howseman; R W Bowtell
Journal:  Philos Trans R Soc Lond B Biol Sci       Date:  1999-07-29       Impact factor: 6.237

5.  Functional MRI for presurgical planning: problems, artefacts, and solution strategies.

Authors:  T Krings; M H Reinges; S Erberich; S Kemeny; V Rohde; U Spetzger; M Korinth; K Willmes; J M Gilsbach; A Thron
Journal:  J Neurol Neurosurg Psychiatry       Date:  2001-06       Impact factor: 10.154

6.  Microfabricated high-moment micrometer-sized MRI contrast agents.

Authors:  Gary Zabow; Stephen J Dodd; Erik Shapiro; John Moreland; Alan P Koretsky
Journal:  Magn Reson Med       Date:  2010-10-06       Impact factor: 4.668

7.  Total neuroenergetics support localized brain activity: implications for the interpretation of fMRI.

Authors:  Fahmeed Hyder; Douglas L Rothman; Robert G Shulman
Journal:  Proc Natl Acad Sci U S A       Date:  2002-07-19       Impact factor: 11.205

Review 8.  Perfusion-weighted magnetic resonance imaging of the brain: techniques and application in children.

Authors:  Thierry A G M Huisman; A Gregory Sorensen
Journal:  Eur Radiol       Date:  2003-06-25       Impact factor: 5.315

Review 9.  Quantification of liver iron with MRI: state of the art and remaining challenges.

Authors:  Diego Hernando; Yakir S Levin; Claude B Sirlin; Scott B Reeder
Journal:  J Magn Reson Imaging       Date:  2014-03-03       Impact factor: 4.813

10.  Slice accelerated gradient-echo spin-echo dynamic susceptibility contrast imaging with blipped CAIPI for increased slice coverage.

Authors:  Cornelius Eichner; Kourosh Jafari-Khouzani; Stephen Cauley; Himanshu Bhat; Pavlina Polaskova; Ovidiu C Andronesi; Otto Rapalino; Robert Turner; Lawrence L Wald; Steven Stufflebeam; Kawin Setsompop
Journal:  Magn Reson Med       Date:  2013-10-28       Impact factor: 4.668

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.