Localized arterial wall drug delivery from a polymer-coated removable metallic stent. Kinetics, distribution, and bioactivity of forskolin.

T L Lambert1, V Dev, E Rechavia, J S Forrester, F Litvack, N L Eigler.   

Abstract

BACKGROUND: Coronary stenting is associated with two major complications: subacute thrombosis and neointimal proliferation resulting in restenosis. Our hypothesis is that the biocompatibility of metallic stents can be improved by coating with a polymer membrane that delivers agents that favorably modify the local arterial microenvironment. This study evaluates the kinetics, distribution, and bioactivity of the model drug forskolin delivered to the local arterial wall by a polyurethane-coated removable metallic stent. METHODS AND
RESULTS: Stents were used in rabbit carotid arteries (n = 20) for as long as 24 hours. The quantity of forskolin bound to the stent decreased exponentially with a half-life of 5.8 hours. Blood concentrations peaked at 140 +/- 39 pg/microL at 4 hours. The adjacent arterial media contained 60 +/- 39 ng/mg, which was 380- and 460-fold greater than the contralateral carotid media and the systemic blood, respectively (P < .0001). Media forskolin concentrations declined exponentially over time with a tissue half-life of 5.0 hours. Drug distributed throughout the vessel wall with decreasing gradients in the radial and axial dimensions consistent with a diffusion process. Removal of the stent was associated with a 100-fold decline in media forskolin concentration within 2 hours. Forskolin release was associated with a sustained 92% increase in carotid blood flow and a 60% decrease in local arterial resistance compared with coated control stents (P < .005). In another set of rabbits (n = 14) using a carotid crush injury, flow-reduction model, forskolin prolonged the time to flow variation and occlusion by 12-fold compared with the use of bare metal stents and 5-fold compared with the use of polyurethane-coated stents (P < .0001).
CONCLUSIONS: A polymer-coated metallic stent can deliver forskolin to the local arterial wall in high concentrations relative to the blood or other tissues. High local drug concentrations are dependent on maintaining stent-to-tissue gradients. The delivered drug is biologically active, demonstrating vasodilating and antiplatelet properties.

Entities:  

Mesh:

Substances:

Year:  1994        PMID: 8044913     DOI: 10.1161/01.cir.90.2.1003

Source DB:  PubMed          Journal:  Circulation        ISSN: 0009-7322            Impact factor:   29.690


  14 in total

1.  Biocompatibility of phosphorylcholine coated stents in normal porcine coronary arteries.

Authors:  D M Whelan; W J van der Giessen; S C Krabbendam; E A van Vliet; P D Verdouw; P W Serruys; H M van Beusekom
Journal:  Heart       Date:  2000-03       Impact factor: 5.994

Review 2.  Invasive assessment of the coronary circulation: intravascular ultrasound and Doppler.

Authors:  David E Newby; Keith A A Fox
Journal:  Br J Clin Pharmacol       Date:  2002-06       Impact factor: 4.335

Review 3.  Coronary artery stents.

Authors:  A J Stewart; D J Coltart
Journal:  Postgrad Med J       Date:  1996-05       Impact factor: 2.401

Review 4.  Biocompatibility issues of implantable drug delivery systems.

Authors:  H Park; K Park
Journal:  Pharm Res       Date:  1996-12       Impact factor: 4.200

5.  Effect of strut distribution on neointimal coverage of everolimus-eluting bioresorbable scaffolds: an optical coherence tomography study.

Authors:  Takao Sato; John Jose; Abdelhakim Allai; Mohamed El-Mawardy; Ralph Tölg; Gert Richardt; Mohamed Abdel-Wahab
Journal:  J Thromb Thrombolysis       Date:  2017-08       Impact factor: 2.300

6.  Synthesis, characterization, and paclitaxel release from a biodegradable, elastomeric, poly(ester urethane)urea bearing phosphorylcholine groups for reduced thrombogenicity.

Authors:  Yi Hong; Sang-Ho Ye; Anca L Pelinescu; William R Wagner
Journal:  Biomacromolecules       Date:  2012-10-18       Impact factor: 6.988

7.  Deposition of nanoparticles in the arterial vessel by porous balloon catheters: localization by confocal laser scanning microscopy and transmission electron microscopy.

Authors:  Ulrich Westedt; Lucian Barbu-Tudoran; Andreas K Schaper; Marc Kalinowski; Heiko Alfke; Thomas Kissel
Journal:  AAPS PharmSci       Date:  2002

Review 8.  Controlled release for local delivery of drugs: barriers and models.

Authors:  Jennifer R Weiser; W Mark Saltzman
Journal:  J Control Release       Date:  2014-05-04       Impact factor: 9.776

9.  Comparisons of the effects of stent eccentricity on the neointimal hyperplasia between sirolimus-eluting stent versus paclitaxel-eluting stent.

Authors:  Byeong-Keuk Kim; Young-Guk Ko; Seungjin Oh; Jung-Sun Kim; Woong Chol Kang; Dong Woon Jeon; Joo Young Yang; Donghoon Choi; Myeong-Ki Hong; Taehoon Ahn; Yangsoo Jang
Journal:  Yonsei Med J       Date:  2010-11       Impact factor: 2.759

10.  Evaluation of fluorinated polymers as coronary stent coating.

Authors:  I Verweire; E Schacht; B P Qiang; K Wang; I De Scheerder
Journal:  J Mater Sci Mater Med       Date:  2000-04       Impact factor: 3.896

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.