Tightening characteristics for screwed joints in osseointegrated dental implants.

R L Burguete1, R B Johns, T King, E A Patterson.   

Abstract

The significance of tightening abutment screws and gold cylinders to osseointegrated fixtures with the correct torque is demonstrated, and a simple relationship between applied torque and screw preload is derived by use of mechanical engineering principles. The principles of a number of tightening methods are outlined and assessments made of their accuracy. The difference between optimum and design torque is highlighted. The necessity and means of achieving optimum torque to ensure a reliable joint in clinical practice is discussed.

Mesh:

Substances:

Year:  1994        PMID: 8040822     DOI: 10.1016/0022-3913(94)90443-x

Source DB:  PubMed          Journal:  J Prosthet Dent        ISSN: 0022-3913            Impact factor:   3.426


  24 in total

1.  A Simple and Cost Effective Method used for Removal of a Fractured Implant Abutment Screw: A Case Report.

Authors:  Parth Satwalekar; K Subash Chander; B Anantha Reddy; N Sandeep; N Sandeep; Tanushree Satwalekar
Journal:  J Int Oral Health       Date:  2013-10-26

2.  Digital evaluation of the reproducibility of implant scanbody fit--an in vitro study.

Authors:  Michael Stimmelmayr; Jan-Frederik Güth; Kurt Erdelt; Daniel Edelhoff; Florian Beuer
Journal:  Clin Oral Investig       Date:  2011-06-04       Impact factor: 3.573

3.  Effect of cement washout on loosening of abutment screws and vice versa in screw- and cement- retained implant-supported dental prosthesis.

Authors:  Seok-Gyu Kim; Chae-Heon Chung; Mee-Kyoung Son
Journal:  J Adv Prosthodont       Date:  2015-06-23       Impact factor: 1.904

4.  Influence of abutment materials on the implant-abutment joint stability in internal conical connection type implant systems.

Authors:  Jae-Young Jo; Dong-Seok Yang; Jung-Bo Huh; Jae-Chan Heo; Mi-Jung Yun; Chang-Mo Jeong
Journal:  J Adv Prosthodont       Date:  2014-12-17       Impact factor: 1.904

5.  The effect of sterilization and number of use on the accuracy of friction-style mechanical torque limiting devices for dental implants.

Authors:  Ali Fayaz; Minoo Mahshid; Aboulfazl Saboury; Seyed Jalil Sadr; Ghassem Ansari
Journal:  Dent Res J (Isfahan)       Date:  2014-01

6.  Influence of the implant-abutment connection design and diameter on the screw joint stability.

Authors:  Hyon-Mo Shin; Jung-Bo Huh; Mi-Jeong Yun; Young-Chan Jeon; Brian Myung Chang; Chang-Mo Jeong
Journal:  J Adv Prosthodont       Date:  2014-04-22       Impact factor: 1.904

7.  A rationale method for evaluating unscrewing torque values of prosthetic screws in dental implants.

Authors:  Felipe Miguel Saliba; Mayra Cardoso; Marcelo Ferreira Torres; Alexandre Carvalho Teixeira; Eduardo José Veras Lourenço; Daniel de Moraes Telles
Journal:  J Appl Oral Sci       Date:  2011 Jan-Feb       Impact factor: 2.698

8.  The effect of aging on the accuracy of new friction-style mechanical torque limiting devices for dental implants.

Authors:  Aboulfazl Saboury; Seyed Jalil Sadr; Ali Fayaz; Minoo Mahshid
Journal:  J Dent (Tehran)       Date:  2013-01-31

9.  Influence of the implant abutment types and the dynamic loading on initial screw loosening.

Authors:  Eun-Sook Kim; Soo-Yeon Shin
Journal:  J Adv Prosthodont       Date:  2013-02-28       Impact factor: 1.904

10.  The effect of steam sterilization on the accuracy of spring-style mechanical torque devices for dental implants.

Authors:  Minoo Mahshid; Aboulfazl Saboury; Ali Fayaz; Seyed Jalil Sadr; Friedrich Lampert; Maziar Mir
Journal:  Clin Cosmet Investig Dent       Date:  2012-07-31
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.