Literature DB >> 8037273

Primary stability of interference screw fixation. Influence of screw diameter and insertion torque.

D Kohn1, C Rose.   

Abstract

Interference screw fixation is frequently used in anterior cruciate ligament reconstruction with the bone-patellar tendon-bone graft. There have been no data available about the influence of screw diameter and insertion torque on primary stability. We designed a cadaveric study using paired knees to analyze the comparative effectiveness of 20-mm long screws of different diameters (9 mm versus 7 mm) and the significance of torque during screw insertion. Testing to failure was performed in a tensiometer with a crosshead speed of 200 mm/min. After slippage of a bone peg in the 7-mm screw specimens, the experiment was repeated in each specimen with a 9-mm screw fixation. Maximum tensile force was greater at the femoral insertion than at the tibial site. Results of refixations with 9-mm screws were only slightly inferior to the original 9-mm screw fixation specimens. Our results further showed that the torque can be used as a predictor of the stability of the bone block but cannot be used as an indicator for the strength of the reconstruction. The 7-mm screws are not recommended for tibial fixation. Failed 7-mm screw fixations can be replaced by 9-mm screws and refixations were successful in our study model.

Entities:  

Mesh:

Year:  1994        PMID: 8037273     DOI: 10.1177/036354659402200307

Source DB:  PubMed          Journal:  Am J Sports Med        ISSN: 0363-5465            Impact factor:   6.202


  22 in total

1.  Analysis of initial fixation strength of press-fit fixation technique in anterior cruciate ligament reconstruction. A comparative study with titanium and bioabsorbable interference screw using porcine lower limb.

Authors:  Myung Chul Lee; Hyunchul Jo; Tae-Soo Bae; Jin Dae Jang; Sang Cheol Seong
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2003-03-06       Impact factor: 4.342

2.  Post-operative assessment of an implant fixation in anterior cruciate ligament reconstructive surgery.

Authors:  Mahmoud Chizari; Martyn Snow; Bin Wang
Journal:  J Med Syst       Date:  2010-05-02       Impact factor: 4.460

3.  Bone mineral density of the proximal metaphysis of tibia: clinical relevance in posterior cruciate ligament reconstruction.

Authors:  Pier Paolo Mariani; Fabrizio Margheritini; Alberto Bellelli
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2005-02-01       Impact factor: 4.342

4.  [Histological findings for human tibial bone-tendon healing after hamstring transplantation. Investigation of tibial insertion after reconstruction of anterior cruciate ligaments with hamstring transplantation near joint fixation using bioresorbable interference screws].

Authors:  C-E Heyde; V Wiechmann; M Pyschik; A Gosse
Journal:  Unfallchirurg       Date:  2006-05       Impact factor: 1.000

Review 5.  Intraarticular migration of a broken biodegradable interference screw after anterior cruciate ligament reconstruction.

Authors:  M H Baums; B A Zelle; W Schultz; T Ernstberger; H-M Klinger
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2006-02-15       Impact factor: 4.342

Review 6.  Graft fixation alternatives in anterior cruciate ligament reconstruction.

Authors:  Bernardino Saccomanni
Journal:  Musculoskelet Surg       Date:  2011-05-03

7.  Fixation strength of biocomposite wedge interference screw in ACL reconstruction: effect of screw length and tunnel/screw ratio. A controlled laboratory study.

Authors:  Antonio Herrera; Fernando Martínez; Daniel Iglesias; José Cegoñino; Elena Ibarz; Luis Gracia
Journal:  BMC Musculoskelet Disord       Date:  2010-06-30       Impact factor: 2.362

8.  Influence of hydroxyapatite-coated and growth factor-releasing interference screws on tendon-bone healing in an ovine model.

Authors:  Yan Lu; Mark D Markel; Brett Nemke; J Sam Lee; Ben K Graf; William L Murphy
Journal:  Arthroscopy       Date:  2009-11-06       Impact factor: 4.772

9.  Torsional stability of interference screws derived from bovine bone--a biomechanical study.

Authors:  Joscha Bauer; Turgay Efe; Silke Herdrich; Leo Gotzen; Bilal Farouk El-Zayat; Jan Schmitt; Nina Timmesfeld; Markus Dietmar Schofer
Journal:  BMC Musculoskelet Disord       Date:  2010-05-01       Impact factor: 2.362

10.  Donor-site morbidity after harvest of a bone-tendon-bone patellar tendon autograft.

Authors:  D Kohn; A Sander-Beuermann
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  1994       Impact factor: 4.342

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.