Literature DB >> 8037036

Detection of infection in loosened hip prostheses: efficacy of sonography.

M T van Holsbeeck1, W R Eyler, L S Sherman, T J Lombardi, E Mezger, J J Verner, J R Schurman, K Jonsson.   

Abstract

OBJECTIVE: The purpose of this study was to determine the efficacy of sonography in the detection of infection in loosened hip prostheses.
MATERIALS AND METHODS: The normal capsular morphology in 15 asymptomatic patients with total hip replacements was studied sonographically. Sonograms were then obtained in 33 patients who had pain in the hip after arthroplasty and radiologic findings of loosening of the prosthesis. These patients subsequently underwent aspiration and arthrography of the hip. Six of the 33 symptomatic patients proved to have prosthetic joint infection.
RESULTS: On sonograms, the normal pseudocapsule is adherent to the proximal part of the anterior femoral cortex, and the capsule-to-bone distance is less than 3.2 mm (average, 2.6 mm). No hips with a capsule-to-bone distance less than 3.2 mm were infected. Sonograms in the six patients with infection showed marked intraarticular effusion with a mean capsule-to-bone distance of 10.2 mm. Five of these six had extracapsular fluid collections. Two patients with hip dislocations and four with aseptic loosening of the prosthesis had capsular distension on sonograms and cultures of aspirated material that showed no growth.
CONCLUSION: Sonography can be used to diagnose infection around loosened hip prostheses. All patients who had an intraarticular effusion with extraarticular extension seen on sonograms had infection.

Entities:  

Mesh:

Year:  1994        PMID: 8037036     DOI: 10.2214/ajr.163.2.8037036

Source DB:  PubMed          Journal:  AJR Am J Roentgenol        ISSN: 0361-803X            Impact factor:   3.959


  16 in total

1.  Gray-scale and color Doppler ultrasonographic evaluation of reactivated post-traumatic/postoperative chronic osteomyelitis.

Authors:  A P Balanika; O Papakonstantinou; C J Kontopoulou; C S Baltas; S Athanassia; K Kanelakopoulou; E Brountzos; A Gouliamos; N L Kelekis
Journal:  Skeletal Radiol       Date:  2008-12-10       Impact factor: 2.199

2.  Therapy with pulsed electromagnetic fields in aseptic loosening of total hip protheses: a prospective study.

Authors:  K Konrad; K Sevcic; K Földes; E Piroska; E Molnár
Journal:  Clin Rheumatol       Date:  1996-07       Impact factor: 2.980

Review 3.  The role of ultrasound in the assessment of post-operative complications following hip arthroplasty.

Authors:  H Douis; D J Dunlop; A M Pearson; J N O'Hara; S L J James
Journal:  Skeletal Radiol       Date:  2012-03-17       Impact factor: 2.199

4.  Accuracy of CT-guided joint aspiration in patients with suspected infection status post-total hip arthroplasty.

Authors:  Xavier Tomas; Guillem Bori; Sebastián Garcia; Ana Isabel Garcia-Diez; Jaime Pomes; Alex Soriano; Jose Ríos; Manel Almela; Josep Mensa; Xavier Gallart; Juan Carlos Martinez; Josep Riba
Journal:  Skeletal Radiol       Date:  2010-05-08       Impact factor: 2.199

5.  Fluoroscopy- vs ultrasound-guided aspiration techniques in the management of periprosthetic joint infection: which is the best?

Authors:  Filippo Randelli; Marco Brioschi; Pietro Randelli; Federico Ambrogi; Silvana Sdao; Alberto Aliprandi
Journal:  Radiol Med       Date:  2017-09-20       Impact factor: 3.469

Review 6.  Current applications of advanced cross-sectional imaging techniques in evaluating the painful arthroplasty.

Authors:  Carolyn M Sofka
Journal:  Skeletal Radiol       Date:  2006-12-06       Impact factor: 2.199

7.  Ultrasound findings in asymptomatic patients with modular metal on metal total hip arthroplasty.

Authors:  Nicholas B Frisch; Nolan M Wessell; Kevin Taliaferro; Marnix Van Holsbeeck; Craig D Silverton
Journal:  Skeletal Radiol       Date:  2017-02-15       Impact factor: 2.199

8.  The role of ultrasonography in the assessment of peri-prosthetic hip complications.

Authors:  Silvana Sdao; Davide Orlandi; Alberto Aliprandi; Francesca Lacelli; Luca Maria Sconfienza; Filippo Randelli; Francesco Sardanelli; Giovanni Serafini
Journal:  J Ultrasound       Date:  2014-06-27

9.  No association between pseudotumors, high serum metal-ion levels and metal hypersensitivity in large-head metal-on-metal total hip arthroplasty at 5-7-year follow-up.

Authors:  Mette Holm Hjorth; Maiken Stilling; Kjeld Soballe; Lars Hans Bolvig; Jacob Pontoppidan Thyssen; Inger Mechlenburg; Stig Storgaard Jakobsen
Journal:  Skeletal Radiol       Date:  2015-10-10       Impact factor: 2.199

10.  Dynamics of hip joint effusion after posterior soft tissue repair in total hip arthroplasty.

Authors:  Sarunas Tarasevicius; Uldis Kesteris; Romas Jonas Kalesinskas; Hans Wingstrand
Journal:  Int Orthop       Date:  2006-03-07       Impact factor: 3.075

View more