Literature DB >> 8024844

Failure mechanisms in human vertebral cancellous bone.

D P Fyhrie1, M B Schaffler.   

Abstract

Specimens of human vertebral cancellous bone were compressed to well past mechanical failure (15% strain) in the infero-superior direction. The mechanisms of failure were examined microscopically and histologically. The primary mechanism of failure was shown to be microscopic cracking rather than overt failure of the trabecular elements. The morphology of the cracks was consistent with an hypothesis that they were the result of shear stress (or strain) in the tissue. Complete fracture of trabeculae was confined to elements oriented transversely to the direction of loading. The tissue's ultimate strength and residual strength after compressive failure were both strongly correlated to tissue stiffness (R2 = 0.88 and R2 = 0.71, respectively). It is proposed that cancellous bone strength may be a consequence of the adaptation of bone stiffness to applied stresses. With removal of the load, all specimens recovered at least 94% of their original height. Implications of energy dissipation by microcracking for recovery and maintenance of overall trabecular architecture are discussed.

Entities:  

Mesh:

Year:  1994        PMID: 8024844     DOI: 10.1016/8756-3282(94)90900-8

Source DB:  PubMed          Journal:  Bone        ISSN: 1873-2763            Impact factor:   4.398


  30 in total

1.  Bone quality.

Authors:  Ego Seeman
Journal:  Osteoporos Int       Date:  2003-08-29       Impact factor: 4.507

2.  Effects of non-enzymatic glycation on cancellous bone fragility.

Authors:  S Y Tang; U Zeenath; D Vashishth
Journal:  Bone       Date:  2006-12-21       Impact factor: 4.398

3.  Effects of hip abductor muscle forces and knee boundary conditions on femoral neck stresses during simulated falls.

Authors:  W J Choi; P A Cripton; S N Robinovitch
Journal:  Osteoporos Int       Date:  2014-07-16       Impact factor: 4.507

4.  Fatigue-induced microdamage in cancellous bone occurs distant from resorption cavities and trabecular surfaces.

Authors:  M G Goff; F M Lambers; T M Nguyen; J Sung; C M Rimnac; C J Hernandez
Journal:  Bone       Date:  2015-05-22       Impact factor: 4.398

5.  Are we crying Wolff? 3D printed replicas of trabecular bone structure demonstrate higher stiffness and strength during off-axis loading.

Authors:  Zach Wood; Lisa Lynn; Jack T Nguyen; Margaret A Black; Meha Patel; Meir M Barak
Journal:  Bone       Date:  2019-08-04       Impact factor: 4.398

6.  Potential of in vivo MRI-based nonlinear finite-element analysis for the assessment of trabecular bone post-yield properties.

Authors:  Ning Zhang; Jeremy F Magland; Chamith S Rajapakse; Yusuf A Bhagat; Felix W Wehrli
Journal:  Med Phys       Date:  2013-05       Impact factor: 4.071

7.  Relationships among ultrasonic and mechanical properties of cancellous bone in human calcaneus in vitro.

Authors:  Keith A Wear; Srinidhi Nagaraja; Maureen L Dreher; Saghi Sadoughi; Shan Zhu; Tony M Keaveny
Journal:  Bone       Date:  2017-06-27       Impact factor: 4.398

8.  Vertebral fragility and structural redundancy.

Authors:  Aaron J Fields; Shashank Nawathe; Senthil K Eswaran; Michael G Jekir; Mark F Adams; Panayiotis Papadopoulos; Tony M Keaveny
Journal:  J Bone Miner Res       Date:  2012-10       Impact factor: 6.741

9.  Variations in nanomechanical properties and tissue composition within trabeculae from an ovine model of osteoporosis and treatment.

Authors:  Jayme C Burket; Daniel J Brooks; Jennifer M MacLeay; Shefford P Baker; Adele L Boskey; Marjolein C H van der Meulen
Journal:  Bone       Date:  2012-10-23       Impact factor: 4.398

10.  Shear strength behavior of human trabecular bone.

Authors:  Arnav Sanyal; Atul Gupta; Harun H Bayraktar; Ronald Y Kwon; Tony M Keaveny
Journal:  J Biomech       Date:  2012-08-09       Impact factor: 2.712

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.