Literature DB >> 8023428

In vitro evaluation of three-dimensional ultrasonography in volume estimation of abdominal organs.

O H Gilja1, N Thune, K Matre, T Hausken, S Odegaard, A Berstad.   

Abstract

The purpose of this study was to evaluate the accuracy and precision of a three-dimensional (3D) ultrasound system in volume estimation of abdominal organs in vitro. A mechanical sector scanner coupled to a stepping motor recorded images of porcine stomach and kidneys. The transducer was tilted through 88 degrees yielding 81 frames, and volume estimation was performed digitally after interactive manual contour indication and organ reconstruction in 3 dimensions. This 3D system showed good correlation (r = 0.998) between estimated and true volumes. Volume estimation of stomach and kidneys using 3.25 MHz probe demonstrated limits of agreement of 0.877 to 1.146 and 1.007 to 1.125, respectively, depicting estimated volumes as a proportion of true volumes in 95% of the examinations. Intra- and interobserver variation of the tracing procedure revealed low values. We conclude that this 3D ultrasound system performs high accuracy and precision in volume estimation.

Mesh:

Year:  1994        PMID: 8023428     DOI: 10.1016/0301-5629(94)90080-9

Source DB:  PubMed          Journal:  Ultrasound Med Biol        ISSN: 0301-5629            Impact factor:   2.998


  17 in total

1.  Gastric emptying measured by ultrasonography.

Authors:  Odd Helge Gilja; Trygve Hausken; Svein degaard; Arnold Berstad
Journal:  World J Gastroenterol       Date:  1999-04       Impact factor: 5.742

2.  Potential of three-dimensional ultrasound in neonatal and paediatric neurosonography.

Authors:  M Riccabona; T R Nelson; C Weitzer; B Resch; D P Pretorius
Journal:  Eur Radiol       Date:  2003-03-06       Impact factor: 5.315

3.  Relationships between gastric accommodation and gastrointestinal sensations in healthy volunteers. A study using the barostat technique and two- and three-dimensional ultrasonography.

Authors:  M W Mundt; T Hausken; A J P M Smout; M Samsom
Journal:  Dig Dis Sci       Date:  2005-09       Impact factor: 3.199

Review 4.  Gastric accommodation assessed by ultrasonography.

Authors:  Odd Helge Gilja; Johan Lunding; Trygve Hausken; Hans Gregersen
Journal:  World J Gastroenterol       Date:  2006-05-14       Impact factor: 5.742

5.  Fundal dysaccommodation in functional dyspepsia: head-to-head comparison between the barostat and three-dimensional ultrasonographic technique.

Authors:  M W Mundt; M Samsom
Journal:  Gut       Date:  2006-01-26       Impact factor: 23.059

6.  Three-dimensional ultrasound scanning.

Authors:  Aaron Fenster; Grace Parraga; Jeff Bax
Journal:  Interface Focus       Date:  2011-06-01       Impact factor: 3.906

Review 7.  Three-dimensional ultrasound as a predictor of pregnancy in patients undergoing ART.

Authors:  Cemil Yaman; Richard Mayer
Journal:  J Turk Ger Gynecol Assoc       Date:  2012-06-01

8.  Feasibility and application of 3-dimensional ultrasound for measurement of gastric volumes in healthy adults and adolescents.

Authors:  Mhd Louai Manini; Duane D Burton; Duane D Meixner; Deborah J Eckert; Matthew Callstrom; Grant Schmit; Mounif El-Youssef; Michael Camilleri
Journal:  J Pediatr Gastroenterol Nutr       Date:  2009-03       Impact factor: 2.839

Review 9.  Advanced imaging and visualization in gastrointestinal disorders.

Authors:  Odd Helge Gilja; Jan G Hatlebakk; Svein Odegaard; Arnold Berstad; Ivan Viola; Christopher Giertsen; Trygve Hausken; Hans Gregersen
Journal:  World J Gastroenterol       Date:  2007-03-07       Impact factor: 5.742

10.  Correlations between the various methods of estimating prostate volume: transabdominal, transrectal, and three-dimensional US.

Authors:  Sun Ho Kim; Seung Hyup Kim
Journal:  Korean J Radiol       Date:  2008 Mar-Apr       Impact factor: 3.500

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.