Literature DB >> 8021531

Algorithm effects on computerized vessel analysis from digitized cine film and a new method of generating the centerline of a vessel.

Y Yanagihara1, T Sugahara.   

Abstract

This study concerns methods of accurately measuring vessel diameters using coronary cineangiograms. Various edge detection filters are compared and a new method for determining the centerline of a vessel is developed. Vessel phantoms of different sizes are used to evaluate the precision and accuracy of an entropy filter, a combined first and second derivative filter, a Laplace-Gaussian filter, a first derivative filter and a second derivative filter. The entropy filter is found to yield the most reliable, precise and accurate data. For use in a clinical case with an irregular arterial wall, a new method of determining the centerline is delineated in which the centerline of a vessel (which we define as a set of points having equal distance to each of any two opposite edge lines) is calculated with images called distance maps. We find that this method of detecting the centerline provides an acceptable assessment of the centerline on visual evaluation.

Mesh:

Year:  1994        PMID: 8021531     DOI: 10.1007/bf01151581

Source DB:  PubMed          Journal:  Int J Card Imaging        ISSN: 0167-9899


  9 in total

1.  Observer agreement in evaluating coronary angiograms.

Authors:  K M Detre; E Wright; M L Murphy; T Takaro
Journal:  Circulation       Date:  1975-12       Impact factor: 29.690

2.  An objective computer system for the quantification of artery stenoses.

Authors:  P F Wankling; R A Perry; A Seth; A C Hunt; X Escaned; J A Newell; M F Shiu
Journal:  Int J Card Imaging       Date:  1990

3.  Interobserver variability in coronary angiography.

Authors:  L M Zir; S W Miller; R E Dinsmore; J P Gilbert; J W Harthorne
Journal:  Circulation       Date:  1976-04       Impact factor: 29.690

4.  Coronary artery dimensions from cineangiograms methodology and validation of a computer-assisted analysis procedure.

Authors:  J H Reiber; C J Kooijman; C J Slager; J J Gerbrands; J C Schuurbiers; A Den Boer; W Wijns; P W Serruys; P G Hugenholtz
Journal:  IEEE Trans Med Imaging       Date:  1984       Impact factor: 10.048

5.  Automated identification of vessel contours in coronary arteriograms by an adaptive tracking algorithm.

Authors:  Y Sun
Journal:  IEEE Trans Med Imaging       Date:  1989       Impact factor: 10.048

6.  Measurement of distensibility of blood vessels using cineangiograms.

Authors:  T Sugahara; Y Yanagihara; C Uyama; H Maeda; M Takafuchi; T Azumi
Journal:  Invest Radiol       Date:  1989-09       Impact factor: 6.016

7.  Cinevideodensitometric analysis of the effect of coronary angioplasty on coronary stenotic dimensions.

Authors:  A B Nichols; A D Berke; J Han; D S Reison; R M Watson; E R Powers
Journal:  Am Heart J       Date:  1988-04       Impact factor: 4.749

8.  Assessment of coronary angioplasty: comparison of visual assessment, hand-held caliper measurement and automated digital quantitation.

Authors:  D Katritsis; D A Lythall; I C Cooper; A Crowther; M M Webb-Peploe
Journal:  Cathet Cardiovasc Diagn       Date:  1988

9.  Computer assessment of hemodynamic severity of coronary artery stenosis from angiograms.

Authors:  M Siebes; D Z D'Argenio; R H Selzer
Journal:  Comput Methods Programs Biomed       Date:  1985-11       Impact factor: 5.428

  9 in total
  1 in total

1.  A new method for automatic identification of coronary arteries in standard biplane angiograms.

Authors:  Y Yanagihara; T Hashimoto; T Sugahara; N Sugimoto
Journal:  Int J Card Imaging       Date:  1994-12
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.