Assessment of coronary angioplasty: comparison of visual assessment, hand-held caliper measurement and automated digital quantitation.

D Katritsis1, D A Lythall, I C Cooper, A Crowther, M M Webb-Peploe.   

Abstract

Digital subtraction coronary angiograms (DSA) of 27 patients who had undergone coronary angioplasty (PTCA) to a total of 32 lesions were analyzed using an automated border-detecting computer program and hand-held caliper measurement of diameter percent stenosis. The results were compared with visual interpretation of the 35-mm cineangiograms. Visual reports significantly overestimated the pre-PTCA diameter percent stenosis (P less than .001) and underestimated the residual post-PTCA narrowing compared with the automatic computer program (P less than .001). Caliper measurements overestimated significantly the pre-PTCA stenosis in comparison with the computer (P less than .01), but post-PTCA the two methods did not differ significantly (P = .105). There was a positive but poor correlation between caliper and computer measurements (r = .43, P less than .05) performed on the pre-PTCA digital angiograms. Post-PTCA the two methods correlated better (r = 0.78, P less than .001), but further statistical analysis showed important discrepancies between them. The correlation of visual reports and computer measurements was poor pre-PTCA (Kendall's tau = 0.32, P less than .05) and not statistically significant post-PTCA (tau = 0.64, P = .5). We conclude that there is observer bias in the visual reporting of angioplasty results, so that pre-PTCA lesions are overestimated, whereas post-PTCA are underestimated. Hand-held caliper measurement improves the assessment of coronary stenoses in comparison with the visual report but still may not altogether eliminate observer bias; it may overestimate the pre-PTCA stenoses compared with automated border detection.

Entities:  

Mesh:

Year:  1988        PMID: 2976306     DOI: 10.1002/ccd.1810150406

Source DB:  PubMed          Journal:  Cathet Cardiovasc Diagn        ISSN: 0098-6569


  6 in total

1.  Development of digital subtraction angiography for coronary artery.

Authors:  Megumi Yamamoto; Yasuhiko Okura; Masaharu Ishihara; Masayuki Kagemoto; Kengo Harada; Takayuki Ishida
Journal:  J Digit Imaging       Date:  2008-03-20       Impact factor: 4.056

2.  Planning for coronary angioplasty: guidelines for training and continuing competence.

Authors:  M M Webb-Peploe
Journal:  Heart       Date:  1996-08       Impact factor: 5.994

Review 3.  Novel QCA methodologies and angiographic scores.

Authors:  Vivian G Ng; Alexandra J Lansky
Journal:  Int J Cardiovasc Imaging       Date:  2011-02-20       Impact factor: 2.357

4.  Comparative cath-lab assessment of coronary stenosis by radiology technician, junior and senior interventional cardiologist in patients treated with coronary angioplasty.

Authors:  Natale Daniele Brunetti; Felice Delli Carri; Maria Assunta Ruggiero; Andrea Cuculo; Antonio Ruggiero; Luigi Ziccardi; Luisa De Gennaro; Matteo Di Biase
Journal:  Interv Med Appl Sci       Date:  2014-03-14

5.  A new method for automatic identification of coronary arteries in standard biplane angiograms.

Authors:  Y Yanagihara; T Hashimoto; T Sugahara; N Sugimoto
Journal:  Int J Card Imaging       Date:  1994-12

6.  Algorithm effects on computerized vessel analysis from digitized cine film and a new method of generating the centerline of a vessel.

Authors:  Y Yanagihara; T Sugahara
Journal:  Int J Card Imaging       Date:  1994-03