Effects of filtration, collimation, and target-receptor distance on artificial approximal enamel lesion detection with the use of RadioVisioGraphy.

E T Parks1, D A Miles, M L Van Dis, G F Williamson, T F Razmus, S L Bricker.   

Abstract

RadioVisioGraphy is an imaging modality that uses a charge-coupled device electronic sensor. Dental charge-coupled device imaging can be used to detect dental caries; however, it was not known what effect beam collimation, added filtration, or variable target-receptor distance has on this task. The purpose of this investigation was to study these effects were imaged by conventional radiography and RadioVisioGraphy varying exposure time, target-receptor distance, collimation, and filtration. Printed RadioVisioGraphy images without enhancement and E-speed radiographs were evaluated by five viewers. The number of true-positives and false-positives were compared as were sensitivity, specificity, positive and negative predictive values, accuracy, and entrance level radiation exposure. Added filtration reduced the false-positives regardless of collimation or target-receptor distance. True-positives and false-positives were greater at a target-receptor distance of 8 inch at exposures < 0.10 seconds (F < 0.0151). E-speed radiographs had a greater specificity and positive predictive value than RadioVisioGraphy images without image enhancement; however, no significant differences were found between RadioVisioGraphy images and E-speed radiographs in true-positive or false-positive identifications without image enhancement.

Mesh:

Substances:

Year:  1994        PMID: 8015809     DOI: 10.1016/0030-4220(94)90207-0

Source DB:  PubMed          Journal:  Oral Surg Oral Med Oral Pathol        ISSN: 0030-4220


  3 in total

1.  Alternative X-ray filters for an intra-oral digital radiographic system.

Authors:  J Stecke; A D Cruz; S M Almeida; F N Bóscolo
Journal:  Dentomaxillofac Radiol       Date:  2012-01-26       Impact factor: 2.419

2.  Performance of a photostimulable storage phosphor digital system with or without the sharpen filter and cone beam CT for detecting approximal enamel subsurface demineralization.

Authors:  M D F Belém; C P M Tabchoury; R I Ferreira-Santos; F C Groppo; F Haiter-Neto
Journal:  Dentomaxillofac Radiol       Date:  2013-02-14       Impact factor: 2.419

Review 3.  Cryptosporidiosis: an emerging, highly infectious threat.

Authors:  R L Guerrant
Journal:  Emerg Infect Dis       Date:  1997 Jan-Mar       Impact factor: 6.883

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.