Literature DB >> 8012134

[Effect of change in refraction by increasing intraocular pressure with the suction cup method on pattern reversal VECP].

F Rohrwacher1, A Bernd, C Ulrich, H Teubel, T Barth, W D Ulrich.   

Abstract

When IOP is increased by the suction cup method, refraction changes will occur, depending on the shape of the cup and the height of the IOP increase. Similar refraction changes were simulated in six healthy volunteers by employing spherical and cylindrical glasses during pattern-reversal visual evoked cortical potential (VECP) with various check sizes and amount of contrast. While the pattern-reversal VECP latencies were not influenced, the amplitudes were reduced considerably. By using contact lenses and a suitably shaped suction cup, refraction changes could be compensated for. In 22 healthy volunteers pattern-reversal VECPs were derived with and without the application of contact lenses with artificially raised IOP. A comparison showed that the amplitudes differed significantly. Without contact lenses a negative pressure of more than 40 mmHg resulted in a drop in the amplitudes with a plateau formed between 80 and 120 mmHg. With compensation by contact lenses the amplitudes are found to be unaltered or even slightly increased until a negative pressure of 120 mmHg is reached in the suction cup, after which they drop. Plotting the pattern-reversal VECP amplitudes (obtained with refraction changes being compensated for by contact lenses) against ciliary perfusion pressure, one finds the characteristic curve described by Ulrich et al., suggesting an autoregulative capacity between 15 and 20 mmHg in healthy persons. The latencies, which remain uninfluenced by refraction changes, are also not altered within an IOP increase of 15-20 mmHg.

Entities:  

Mesh:

Year:  1994        PMID: 8012134

Source DB:  PubMed          Journal:  Ophthalmologe        ISSN: 0941-293X            Impact factor:   1.059


  3 in total

1.  New device for artificial increasing intraocular pressure.

Authors:  P R Preussner; A Duran
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  1996-11       Impact factor: 3.117

2.  Influence of suction cup oculopression on corneal astigmatism.

Authors:  U Schiefer; C Ulrich; W D Ulrich; C Petzel; A Bernd; H Wilhelm
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  1994-02       Impact factor: 3.117

3.  Pr VECPs related to ciliary perfusion pressure in primary open angle glaucoma. A study using contact lenses to compensate for refraction changes during artificially raised IOP.

Authors:  F Rohrwacher; C Ulrich; A Bernd; T Barth; W D Ulrich
Journal:  Int Ophthalmol       Date:  1992-09       Impact factor: 2.031

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.