Literature DB >> 8004049

Biomechanical concerns with fixed partial dentures involving implants.

C E English1.   

Abstract

Nine biomechanical factors involved in the design and fabrication of fixed partial dentures incorporating implants are discussed, focusing upon the deleterious effects of leverage, torsion, occlusal overload, and poor oral hygiene. Areas of concern are cantilevers, pier abutments, excessive fixed spans, use and misuse of nonrigid connectors, off-axis loading, occlusal plane to implant height ratio, inadequate support, distribution, and mandibular flexion and torsion.

Mesh:

Substances:

Year:  1993        PMID: 8004049     DOI: 10.1097/00008505-199312000-00002

Source DB:  PubMed          Journal:  Implant Dent        ISSN: 1056-6163            Impact factor:   2.454


  5 in total

1.  Influence of abutment materials on the implant-abutment joint stability in internal conical connection type implant systems.

Authors:  Jae-Young Jo; Dong-Seok Yang; Jung-Bo Huh; Jae-Chan Heo; Mi-Jung Yun; Chang-Mo Jeong
Journal:  J Adv Prosthodont       Date:  2014-12-17       Impact factor: 1.904

2.  Clinical outcomes of single implant supported crowns versus 3-unit implant-supported fixed dental prostheses in Dubai Health Authority: a retrospective study.

Authors:  Sara Hussain Alhammadi; Girvan Burnside; Alexander Milosevic
Journal:  BMC Oral Health       Date:  2021-04-01       Impact factor: 2.757

3.  Survival rates of ultra-short (<6 mm) compared with short locking-taper implants supporting single crowns in posterior areas: A 5-year retrospective study.

Authors:  Giorgio Lombardo; Annarita Signoriello; Mauro Marincola; Pietro Liboni; Estevam A Bonfante; Pier F Nocini
Journal:  Clin Implant Dent Relat Res       Date:  2021-11-18       Impact factor: 4.259

4.  A Comparative Evaluation of the Strain Transmitted through Prostheses on Implants with Two Different Macro-Structures and Connection during Insertion and Loading Phase: An In Vitro Study.

Authors:  Riyam Kassem; Amar Samara; Ameer Biadsee; Shchada Masarwa; Tarek Mtanis; Zeev Ormianer
Journal:  Materials (Basel)       Date:  2022-07-16       Impact factor: 3.748

5.  The effect of mandibular flexure on the design of implant-supported fixed restorations of different facial types under two loading conditions by three-dimensional finite element analysis.

Authors:  Jing Gao; Xuejing Li; Jing He; Lulu Jiang; Baohong Zhao
Journal:  Front Bioeng Biotechnol       Date:  2022-08-29
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.