Literature DB >> 7988056

Quantitative computer image analysis of a human chorionic gonadotropin colloidal carbon dipstick assay.

A van Amerongen1, D van Loon, L B Berendsen, J H Wichers.   

Abstract

Colloidal particles are widely used in qualitative dipstick assays for the determination of various proteins and haptens. Recently, a new colloidal label has been introduced based on elemental carbon. With this carbon label we have prepared a human chorionic gonadotropin-specific dipstick assay with a sensitivity of 10 mIU/ml. In addition, an image- and data-processing procedure for the quantification of the dipstick assay has been developed. The sum of the pixel grey levels of a carbon line was taken as a measure for this quantitative purpose. The measurement range of the assay is almost three orders of magnitude, i.e. 10 mIU/ml to 500 mIU/ml. The deviation from the mean of two dipstick determinations was 1.22% on average. The within-run and between-run precision, expressed as coefficients of variation at 50 mIU/ml were 1.03% and 1.84%, at 150 mIU/ml 2.14% and 3.77% and at 450 mIU/ml 2.55% and 5.28%, respectively. We have correlated this quantitative sol particle immunoassay with a commercial human chorionic gonadotropin specific radioimmunoassay. In an experiment with 25 human urine samples containing the hormone in amounts from 5 to 300 mIU/ml the correlation coefficient was 0.999. The sol particle immunoassay quantified by computer image analysis has been termed Sol particle Image Processed ImmunoAssay (SIPIA).

Entities:  

Mesh:

Substances:

Year:  1994        PMID: 7988056     DOI: 10.1016/0009-8981(94)90229-1

Source DB:  PubMed          Journal:  Clin Chim Acta        ISSN: 0009-8981            Impact factor:   3.786


  3 in total

1.  Diagnosis of schistosomiasis by reagent strip test for detection of circulating cathodic antigen.

Authors:  G J van Dam; J H Wichers; T M Falcao Ferreira; D Ghati; A van Amerongen; A M Deelder
Journal:  J Clin Microbiol       Date:  2004-12       Impact factor: 5.948

Review 2.  Current and emerging trends in point-of-care urinalysis tests.

Authors:  Rongwei Lei; Rannon Huo; Chandra Mohan
Journal:  Expert Rev Mol Diagn       Date:  2019-12-12       Impact factor: 5.225

Review 3.  Amorphous carbon nanoparticles: a versatile label for rapid diagnostic (immuno)assays.

Authors:  Geertruida A Posthuma-Trumpie; Jan H Wichers; Marjo Koets; Luciënne B J M Berendsen; Aart van Amerongen
Journal:  Anal Bioanal Chem       Date:  2011-09-09       Impact factor: 4.142

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.