Literature DB >> 7983255

Clinical status of ten dentin adhesive systems.

B Van Meerbeek1, M Peumans, M Verschueren, S Gladys, M Braem, P Lambrechts, G Vanherle.   

Abstract

Laboratory testing of dentin adhesive systems still requires corroboration by long-term clinical trials for their ultimate clinical effectiveness to be validated. The objective of this clinical investigation was to evaluate, retrospectively, the clinical effectiveness of earlier-investigated dentin adhesive systems (Scotchbond, Gluma, Clearfil New Bond, Scotchbond 2, Tenure, and Tripton), and to compare their clinical results with those obtained with four modern total-etch adhesive systems (Bayer exp. 1 and 2, Clearfil Liner Bond System, and Scotchbond Multi-Purpose). In total, 1177 Class V cervical lesions in the teeth of 346 patients were restored following two cavity designs: In Group A, enamel was neither beveled nor intentionally etched, as per ADA guidelines; in Group B, adjacent enamel was beveled and conditioned. Clinical retention rates definitely indicated the improved clinical efficacy of the newest dentin adhesives over the earlier systems. With regard to adhesion strategy, adhesive systems that removed the smear layer and concurrently demineralized the dentin surface layer performed clinically better than systems that modified the disorderly layer of smear debris without complete removal. Hybridization by resin interdiffusion into the exposed dentinal collagen layer, combined with attachment of resin tags into the opened dentin tubules, appeared to be essential for reliable dentin bonding but might be insufficient by itself. The additional formation of an elastic bonding area as a polymerization shrinkage absorber and the use of a microfine restorative composite apparently guaranteed an efficient clinical result. The perfect one-year retention recorded for Clearfil Liner Bond System and Scotchbond Multi-Purpose must be confirmed at later recalls.

Entities:  

Mesh:

Substances:

Year:  1994        PMID: 7983255     DOI: 10.1177/00220345940730110401

Source DB:  PubMed          Journal:  J Dent Res        ISSN: 0022-0345            Impact factor:   6.116


  13 in total

1.  Dentin infiltration ability of different classes of adhesive systems.

Authors:  Alina Langer; Nicoleta Ilie
Journal:  Clin Oral Investig       Date:  2012-02-29       Impact factor: 3.573

2.  Effect of bacterial collagenase on resin-dentin bonds degradation.

Authors:  Manuel Toledano; Raquel Osorio; Estrella Osorio; Fátima S Aguilera; Monica Yamauti; David H Pashley; Franklin Tay
Journal:  J Mater Sci Mater Med       Date:  2007-06-14       Impact factor: 3.896

3.  Nanohybrid vs. fine hybrid composite in extended class II cavities: 8-year results.

Authors:  Roland Frankenberger; Christian Reinelt; Norbert Krämer
Journal:  Clin Oral Investig       Date:  2013-03-23       Impact factor: 3.573

Review 4.  Retention of tooth-colored restorations in non-carious cervical lesions--a systematic review.

Authors:  Maria Jacinta Moraes Coelho Santos; Nilgun Ari; Shawn Steele; John Costella; David Banting
Journal:  Clin Oral Investig       Date:  2014-03-27       Impact factor: 3.573

Review 5.  Durability of bonds and clinical success of adhesive restorations.

Authors:  Ricardo M Carvalho; Adriana P Manso; Saulo Geraldeli; Franklin R Tay; David H Pashley
Journal:  Dent Mater       Date:  2012-01       Impact factor: 5.304

6.  Response of human pulps capped with different self-etch adhesive systems.

Authors:  M L R Accorinte; A D Loguercio; A Reis; C A S Costa
Journal:  Clin Oral Investig       Date:  2007-11-20       Impact factor: 3.573

7.  To compare the microleakage among experimental adhesives containing nanoclay fillers after the storages of 24 hours and 6 months.

Authors:  Seyed Mostafa Mousavinasab; Mohammad Atai; Bagher Alavi
Journal:  Open Dent J       Date:  2011-03-29

8.  Relationship between Operator Skill and In Vitro Microleakage of Different Adhesive Systems in Class V Restorations.

Authors:  Audrey Guéders; Sabine Geerts
Journal:  ISRN Dent       Date:  2010-11-29

9.  An in vitro evaluation of leakage of two etch and rinse and two self-etch adhesives after thermocycling.

Authors:  Sabine Geerts; Amandine Bolette; Laurence Seidel; Audrey Guéders
Journal:  Int J Dent       Date:  2012-05-22

10.  A comparative analysis of restorative materials used in abfraction lesions in tooth with and without occlusal restoration: Three-dimensional finite element analysis.

Authors:  A Srirekha; Kusum Bashetty
Journal:  J Conserv Dent       Date:  2013-03
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.