Literature DB >> 7979102

Improved method for analysis of glycated haemoglobin by ion exchange chromatography.

S Eckerbom1, Y Bergqvist, J O Jeppsson.   

Abstract

The Pharmacia Mono S column for glycated haemoglobin (HbA1c) was compared with Mono S HR 5/5 and three other cation exchange columns to optimize analysis of HbA1c. This column allows a significant decrease in separation time, resulting in a sample throughput of 12 samples per hour. The choice of parameters for integration of peak areas in the chromatograms is very important for reproducible results. Since pure calibrators of HbA1c are not available, the relative contribution of HbA1c to the total amount of haemoglobin is calculated. We have compared valley-to-valley integration with baseline integration to assess reproducibility. Valley-to-valley integration significantly enhances the reproducibility of the method and is therefore preferable for routine analyses of HbA1c.

Entities:  

Mesh:

Substances:

Year:  1994        PMID: 7979102     DOI: 10.1177/000456329403100409

Source DB:  PubMed          Journal:  Ann Clin Biochem        ISSN: 0004-5632            Impact factor:   2.057


  16 in total

1.  Standardization of HbA1c: good or bad?

Authors:  Sally M Marshall
Journal:  Nat Rev Endocrinol       Date:  2010-05-04       Impact factor: 43.330

2.  Magnetite-Quantum Dot Immunoarray for Plasmon-Coupled-Fluorescence Imaging of Blood Insulin and Glycated Hemoglobin.

Authors:  Vini Singh; Rajasekhara Nerimetla; Ming Yang; Sadagopan Krishnan
Journal:  ACS Sens       Date:  2017-06-23       Impact factor: 7.711

3.  HbA1c standardisation destination--global IFCC Standardisation. How, why, where and when--a tortuous pathway from kit manufacturers, via inter-laboratory lyophilized and whole blood comparisons to designated national comparison schemes.

Authors:  Ian Goodall
Journal:  Clin Biochem Rev       Date:  2005-02

Review 4.  A review of the challenge in measuring hemoglobin A1c.

Authors:  Cas Weykamp; W Garry John; Andrea Mosca
Journal:  J Diabetes Sci Technol       Date:  2009-05-01

5.  HbA1c method evaluation for postmortem samples.

Authors:  Terhi Keltanen; Antti Sajantila; Tiina Valonen; Teija Partanen; Katarina Lindroos
Journal:  Forensic Sci Med Pathol       Date:  2014-12-24       Impact factor: 2.007

6.  Effect of Atorvastatin on Glycaemic Parameters in Normoglycaemic and Prediabetic Subjects: A Prospective, Panel Study.

Authors:  Sansita Parida; Trupti Rekha Swain; Satya Narayan Routray; Rituparna Maiti
Journal:  J Clin Diagn Res       Date:  2017-02-01

7.  Ethnic differences in dissatisfaction with sexual life in patients with type 2 diabetes in a Swedish town.

Authors:  Marina Taloyan; Alexandre Wajngot; Sven-Erik Johansson; Jonas Tovi; Jan Sundquist
Journal:  BMC Public Health       Date:  2010-09-08       Impact factor: 3.295

8.  Analysis and Quantitation of Glycated Hemoglobin by Matrix Assisted Laser Desorption/Ionization Time of Flight Mass Spectrometry.

Authors:  Stephen J Hattan; Kenneth C Parker; Marvin L Vestal; Jane Y Yang; David A Herold; Mark W Duncan
Journal:  J Am Soc Mass Spectrom       Date:  2016-01-05       Impact factor: 3.109

9.  Drug use and increased HbA1c levels in non-diabetic very elderly persons: the Kungsholmen project.

Authors:  Galina Passare; Johan Fastbom; Ove Törring; Matti Viitanen
Journal:  Eur J Clin Pharmacol       Date:  2004-03-10       Impact factor: 2.953

10.  Cardiovascular risk factors in Assyrians/Syrians and native Swedes with type 2 diabetes: a population-based epidemiological study.

Authors:  Marina Taloyan; Alexandre Wajngot; Sven-Erik Johansson; Jonas Tovi; Jan Sundquist
Journal:  Cardiovasc Diabetol       Date:  2009-11-12       Impact factor: 9.951

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.