Literature DB >> 7977099

Feasibility of concomitant implantation of permanent transvenous pacemaker and defibrillator systems.

Z Blanck1, I Niazi, K Axtell, J Sra, M R Jazayeri, A Dhala, S Deshpande, M Akhtar.   

Abstract

In 17 patients (14 men and 3 women aged 69 +/- 10 years), a transvenous pacemaker was implanted before (8 patients), following (7 patients), or simultaneously (2 patients) with the insertion of a transvenous defibrillator. Indications included malignant ventricular arrhythmias and symptomatic bradycardia in all patients. All patients had structural heart disease. All pacemakers were non-programmable bipolar, either single chamber (n = 7) or dual chamber (n = 10). Eleven pacemakers were rate responsive. The Transvene system was implanted in 7 patients (Pacer-Cardioverter-Defibrillator in 6 patients and the Cadence defibrillator in 1). The Endotak lead system was implanted in 10 patients (Ventak in 7 patients and the Cadence in 3). The mean defibrillation threshold was 16 +/- 5 J. Repositioning of the pacemaker leads eliminated undersensing of ventricular fibrillation by the defibrillator, which occurred during asynchronous pacing in 2 patients. During a mean follow-up of 11 +/- 6 months, 2 patients died because of pump failure and 7 patients received defibrillator therapy for ventricular arrhythmias. No significant complications were noted. Successful concomitant implantation of transvenous pacemakers and defibrillators was thus accomplished in 17 patients, which suggests that insertion of a second transvenous device can be safely accomplished.

Entities:  

Mesh:

Year:  1994        PMID: 7977099     DOI: 10.1016/0002-9149(94)90557-6

Source DB:  PubMed          Journal:  Am J Cardiol        ISSN: 0002-9149            Impact factor:   2.778


  4 in total

Review 1.  Implantable dual-chamber cardioverter-defibrillator-pacemaker.

Authors:  D Pfeiffer; M Mende; A Hagendorff
Journal:  Curr Cardiol Rep       Date:  2000-07       Impact factor: 2.931

2.  [Not Available].

Authors:  C Butter; U Kintscher; A Waurick; M Stockburger; E Fleck
Journal:  Herzschrittmacherther Elektrophysiol       Date:  1998-02

3.  Combined use of non-thoracotomy cardioverter defibrillators and endocardial pacemakers.

Authors:  H H Noguera; A O Peralta; R M John; F J Venditti; D T Martin
Journal:  Heart       Date:  1997-07       Impact factor: 5.994

4.  Unique interaction between an atrial single-chamber pacemaker and a ventricular defibrillator.

Authors:  C Sticherling; S A Strickberger; G F Michaud
Journal:  J Interv Card Electrophysiol       Date:  2000-04       Impact factor: 1.900

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.