Literature DB >> 7972804

Liver metastases: safety and efficacy of detection with superparamagnetic iron oxide in MR imaging.

M F Bellin1, S Zaim, E Auberton, G Sarfati, J J Duron, D Khayat, J Grellet.   

Abstract

PURPOSE: To evaluate the clinical and biologic safety of superparamagnetic iron oxide (SPIO) as a contrast agent in magnetic resonance (MR) imaging and to assess its efficacy in the detection of liver metastases.
MATERIALS AND METHODS: Twenty adults with liver metastases underwent MR imaging at 1.5 T before and 1 hour after infusion of SPIO. Four spin-echo (SE) sequences and one gradient-echo (GRE) sequence were used.
RESULTS: There were no adverse reactions. Alterations in serum protein, serum iron, transferrin, and ferritin levels and transferrin saturation coefficient were statistically significant. The mean tumor-to-liver contrast-to-noise ratio (C/N) increased markedly with all sequences. The best postcontrast tumor-to-liver contrast was obtained with the GRE sequence (repetition time msec/echo time msec = 300/15). The mean number of apparent lesions detected after administration of SPIO increased by 12 with the proton-density-weighted SE sequences (800/30 and 2,500/30), four with the T2-weighted SE sequence (2,500/90), and seven with the GRE sequence (300/15).
CONCLUSION: SPIO is safe, increases tumor-to-liver C/Ns with some sequences, and improves the detection of liver metastases.

Entities:  

Mesh:

Substances:

Year:  1994        PMID: 7972804     DOI: 10.1148/radiology.193.3.7972804

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  13 in total

Review 1.  Safety of MR liver specific contrast media.

Authors:  Marie-France Bellin; Judith A W Webb; Aart J Van Der Molen; Henrik S Thomsen; Sameh K Morcos
Journal:  Eur Radiol       Date:  2004-12-31       Impact factor: 5.315

Review 2.  [Molecular and parametric imaging with iron oxides].

Authors:  L Matuszewski; B Tombach; W Heindel; C Bremer
Journal:  Radiologe       Date:  2007-01       Impact factor: 0.635

3.  MR-arterioportography: a new technical approach for detection of liver lesions.

Authors:  Janine Rennert; Ernst-Michael Jung; Andreas G Schreyer; Patrick Hoffstetter; Peter Heiss; Stefan Feuerbach; Niels Zorger
Journal:  World J Gastroenterol       Date:  2011-04-07       Impact factor: 5.742

4.  Towards clinically translatable in vivo nanodiagnostics.

Authors:  Seung-Min Park; Amin Aalipour; Ophir Vermesh; Jung Ho Yu; Sanjiv S Gambhir
Journal:  Nat Rev Mater       Date:  2017-05-03       Impact factor: 66.308

5.  Detection of liver metastases: gadobenate dimeglumine-enhanced three-dimensional dynamic phases and one-hour delayed phase MR imaging versus superparamagnetic iron oxide-enhanced MR imaging.

Authors:  Young Kon Kim; Jeong Min Lee; Chong Soo Kim; Gyung Ho Chung; Chan Young Kim; In Hee Kim
Journal:  Eur Radiol       Date:  2004-12-29       Impact factor: 5.315

6.  Characterization of focal hepatic lesions with SPIO-enhanced MRI.

Authors:  Wei-Wei Zheng; Kang-Rong Zhou; Zu-Wang Chen; Ji-Zhang Shen; Cai-Zhong Chen; Shu-Jie Zhang
Journal:  World J Gastroenterol       Date:  2002-02       Impact factor: 5.742

Review 7.  Imaging of metastases to the liver.

Authors:  A E Mahfouz; B Hamm; D Mathieu
Journal:  Eur Radiol       Date:  1996       Impact factor: 5.315

8.  Detection of colorectal liver metastases: a prospective multicenter trial comparing unenhanced MRI, MnDPDP-enhanced MRI, and spiral CT.

Authors:  Carlo Bartolozzi; Francescamaria Donati; Dania Cioni; Carlo Procacci; Giovanni Morana; Antonio Chiesa; Luigi Grazioli; Giorgio Cittadini; Giuseppe Cittadini; Andrea Giovagnoni; Giovanni Gandini; Jochen Maass; Riccardo Lencioni
Journal:  Eur Radiol       Date:  2003-08-09       Impact factor: 5.315

9.  Detection of colorectal liver metastases: prospective comparison of unenhanced and ferumoxides-enhanced magnetic resonance imaging at 1.5 T, dual-phase spiral CT, and spiral CT during arterial portography.

Authors:  R Lencioni; F Donati; D Cioni; A Paolicchi; A Cicorelli; C Bartolozzi
Journal:  MAGMA       Date:  1998-12       Impact factor: 2.310

10.  Optimal pulse sequence for ferumoxides-enhanced MR imaging used in the detection of hepatocellular carcinoma: a comparative study using seven pulse sequences.

Authors:  Seung Hoon Kim; Dongil Choi; Jae Hoon Lim; Won Jae Lee; Hyun Jung Jang; Hyo Keun Lim; Soon Jin Lee; Jae Min Cho; Seung Kwon Kim; Gab Chul Kim
Journal:  Korean J Radiol       Date:  2002 Apr-Jun       Impact factor: 3.500

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.