Hepatic CT enhancement. Part II. Alterations in contrast material volume and rate of injection within the same patients.

T P Chambers1, R L Baron, R M Lush.   

Abstract

PURPOSE: To evaluate the effects of alterations in contrast material volume and injection rate on liver computed tomographic (CT) enhancement within the same patients.
MATERIALS AND METHODS: Forty patients underwent repeat CT within 6 months, one with 150 mL of nonionic contrast material at 2 mL/sec, the other with 150 mL (n = 8, group A), 100 mL (n = 14, group B), or 180 mL (n = 18, group C) at 3 mL/sec. Comparisons were made only within the same patients.
RESULTS: In group A, mean liver enhancement was greater with the higher rate (3 mL/sec) up to 130 seconds after injection, mean peak liver enhancement was greater by 10 HU, and mean time to peak enhancement was shorter by 15 seconds. In group B, mean peak enhancement was greater with 150 mL by 9 HU, and mean time to peak enhancement was longer by 27 seconds. In group C, peak enhancement and time to peak liver enhancement were greater.
CONCLUSION: Contrast material volume and injection rate have interdependent effects on liver enhancement and potentially tumor conspicuity. Higher rates compensate partially for lower volume, but enhancement is still reduced. The optimal window of time for imaging after injection varies with injection technique.

Entities:  

Mesh:

Substances:

Year:  1994        PMID: 7972771     DOI: 10.1148/radiology.193.2.7972771

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  4 in total

Review 1.  MDCT of primary liver malignancies.

Authors:  Alfonso Marchianò
Journal:  Eur Radiol       Date:  2003-12       Impact factor: 5.315

2.  Multidetector CT imaging of pleura: comparison of two contrast infusion protocols.

Authors:  V Raj; R Kirke; M J Bankart; J J Entwisle
Journal:  Br J Radiol       Date:  2010-12-15       Impact factor: 3.039

3.  Improvement of parenchymal and vascular enhancement using saline flush and power injection for multiple-detector-row abdominal CT.

Authors:  Helmut Schoellnast; Manfred Tillich; Hannes A Deutschmann; Uwe Stessel; Michael J Deutschmann; Gottfried J Schaffler; Renate Schoellnast; Martin M Uggowitzer
Journal:  Eur Radiol       Date:  2003-10-18       Impact factor: 5.315

4.  Contrast media in abdominal computed tomography: optimization of delivery methods.

Authors:  J K Han; B I Choi; A Y Kim; S J Kim
Journal:  Korean J Radiol       Date:  2001 Jan-Mar       Impact factor: 3.500

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.