Literature DB >> 7970562

Sensitivity of random dot stereoacuity and Snellen acuity to optical blur.

P P Schmidt1.   

Abstract

The purpose of this study is to investigate the usefulness of a random dot stereogram for the detection of refractive blur by determining the relative sensitivity of random dot stereoacuity (RDS) and Snellen visual acuity to the effects of optically induced blur. Measurements of Snellen and stereoacuity were compLeted on four young adult subjects under cycloplegia and through artificial pupils. Optical blur was varied binocularly and monocularly in 0.50 D steps up to +/- 6.00 D while the subjects viewed targets composed of stimuli arranged in 0.1 log unit size increments. The results show the relation between RDS and Snellen acuity to be SA = 1.341 (VA) + 0.281 for equal amounts of binocularly induced optical blur. Moreover, the RDS appeared more highly sensitive when the blur in the 2 eyes was unequal [SA = 3.774 (VA) - 1.180], a condition approximating refractive anisometropic amblyopia. These results provide a rationale for the use of random element stereograms for the detection of refractive amblyopia and ametropia in the vision screening of children.

Entities:  

Mesh:

Year:  1994        PMID: 7970562     DOI: 10.1097/00006324-199407000-00007

Source DB:  PubMed          Journal:  Optom Vis Sci        ISSN: 1040-5488            Impact factor:   1.973


  10 in total

1.  The effects of interocular differences in retinal illuminance on vision and binocularity.

Authors:  Yoon-Hee Chang; Jong Bok Lee; Nam Soo Kim; Dong Wook Lee; Jee Ho Chang; Sueng-Han Han
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2006-01-13       Impact factor: 3.117

2.  The effect of induced monocular blur on measures of stereoacuity.

Authors:  Naomi V Odell; Sarah R Hatt; David A Leske; Wendy E Adams; Jonathan M Holmes
Journal:  J AAPOS       Date:  2008-12-13       Impact factor: 1.220

3.  Stereoacuity of preschool children with and without vision disorders.

Authors:  Elise B Ciner; Gui-Shuang Ying; Marjean Taylor Kulp; Maureen G Maguire; Graham E Quinn; Deborah Orel-Bixler; Lynn A Cyert; Bruce Moore; Jiayan Huang
Journal:  Optom Vis Sci       Date:  2014-03       Impact factor: 1.973

4.  Uncorrected Hyperopia and Preschool Early Literacy: Results of the Vision in Preschoolers-Hyperopia in Preschoolers (VIP-HIP) Study.

Authors:  Marjean Taylor Kulp; Elise Ciner; Maureen Maguire; Bruce Moore; Jill Pentimonti; Maxwell Pistilli; Lynn Cyert; T Rowan Candy; Graham Quinn; Gui-Shuang Ying
Journal:  Ophthalmology       Date:  2016-01-27       Impact factor: 12.079

5.  New stereoacuity test using a 3-dimensional display system in children.

Authors:  Sang Beom Han; Hee Kyung Yang; Jonghyun Kim; Keehoon Hong; Byoungho Lee; Jeong-Min Hwang
Journal:  PLoS One       Date:  2015-02-18       Impact factor: 3.240

6.  Monocular blur alters the tuning characteristics of stereopsis for spatial frequency and size.

Authors:  Roger W Li; Kayee So; Thomas H Wu; Ashley P Craven; Truyet T Tran; Kevin M Gustafson; Dennis M Levi
Journal:  R Soc Open Sci       Date:  2016-09-21       Impact factor: 2.963

7.  The effect of dot size in random-dot stereograms on the results of stereoacuity measurements.

Authors:  Lingzhi Zhao; Huang Wu
Journal:  BMC Ophthalmol       Date:  2020-06-24       Impact factor: 2.209

8.  Assessment of stereo acuity levels using random dot stereo acuity chart in college students.

Authors:  B M S Deepa; A Valarmathi; Sharon Benita
Journal:  J Family Med Prim Care       Date:  2019-12-10

9.  Stereoacuity among Undergraduate Medical and Nursing Students at a Tertiary Care Hospital: A Descriptive Cross-sectional Study.

Authors:  Pragati Gautam Adhikari; Sangam Shah; Nikita Bhatta; Prince Mandal; Basanta Sharma Paudel; Apil Pokhrel; Bipin Koirala; Chiranjiwi Prasad Shah
Journal:  JNMA J Nepal Med Assoc       Date:  2022-01-15       Impact factor: 0.556

10.  Apparent sharpness of 3D video when one eye's view is more blurry.

Authors:  Alan Robinson; Ankit Jain; Mathew Scott; Don Macleod; Truong Nguyen
Journal:  Iperception       Date:  2013-08-28
  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.