Shaping X-ray spectra with filters in X-ray diagnostics.

M Sandborg1, C A Carlsson, G A Carlsson.   

Abstract

The influence on image contrast, tube load and patient mean absorbed dose of different ways of shaping diagnostic X-ray spectra by placing filters in the beam is derived fro two radiographic models (abdominal screen-film radiography and intra-oral, dental radiography) using a computational model. The filters are compared at either equal tube load (keeping tube potential constant) or equal contrast (adjusting the tube potential with the different filters), but always at equal energy imparted per unit area to the image receptor. Compared at equal tube load and relative to standard aluminum filtration, reductions in the mean absorbed dose in the patient of 15-25% can be achieved using filters of Cu, Ti, W and Au (increasing the tube load by 30-40% compared with standard aluminium filtration). However, contrast is also reduced by 7%. Compared at equal contrast, the dose reductions are smaller, about 10%. Filters of copper are generally recommended, as are filters of aluminium. The use of bandpass filters (K-edge filters) should be restricted to examinations where the need for substantial variation in tube potential from patient to patient is small. The benefit of using thicker filters than those commonly used today (increasing tube load by factors of 1.4-2.0 compared with no added filter) is small as the dose reduction is most rapid for small initial values of added filters, and the increase in tube load increases steadily with increasing filter thickness.

Entities:  

Mesh:

Year:  1994        PMID: 7967802     DOI: 10.1007/BF02524689

Source DB:  PubMed          Journal:  Med Biol Eng Comput        ISSN: 0140-0118            Impact factor:   2.602


  13 in total

1.  Influence of scattered radiation and tube potential on radiographic contrast: comparison of two different dental X-ray films.

Authors:  E Helmrot; G A Carlsson; O Eckerdal; M Sandborg
Journal:  Dentomaxillofac Radiol       Date:  1991-08       Impact factor: 2.419

2.  Filter materials for dose reduction in screen-film radiography.

Authors:  K Koedooder; H W Venema
Journal:  Phys Med Biol       Date:  1986-06       Impact factor: 3.609

3.  Generalised use of contrast degradation and contrast improvement factors in diagnostic radiology. Application to vanishing contrast.

Authors:  G A Carlsson; C A Carlsson; B Nielsen; J Persliden
Journal:  Phys Med Biol       Date:  1986-07       Impact factor: 3.609

4.  A method for comparing beam-hardening filter materials for diagnostic radiology.

Authors:  R J Jennings
Journal:  Med Phys       Date:  1988 Jul-Aug       Impact factor: 4.071

5.  Samarium filters for dental radiography.

Authors:  A G Richards; G L Barbor; J D Bader; J D Hale
Journal:  Oral Surg Oral Med Oral Pathol       Date:  1970-05

6.  A Monte Carlo program for photon transport using analogue sampling of scattering angle in coherent and incoherent scattering processes.

Authors:  J Persliden
Journal:  Comput Programs Biomed       Date:  1983 Aug-Oct

7.  Evaluation of the use of a niobium filter for patient dose reduction in chest radiography.

Authors:  H Thierens; M Kunnen; A Van der Plaetsen; O Segaert
Journal:  Br J Radiol       Date:  1991-04       Impact factor: 3.039

8.  Clinical use of a gadolinium filter in pediatric radiography.

Authors:  M A Johnson; A E Burgess
Journal:  Pediatr Radiol       Date:  1981

9.  Erbium filtration in iodine contrast studies.

Authors:  R G Previtte
Journal:  Radiol Technol       Date:  1982 Mar-Apr

10.  The effect of rare earth filtration on patient exposure, dose reduction, and image quality in oral panoramic radiology.

Authors:  D A Tyndall; D B Washburn
Journal:  Health Phys       Date:  1987-01       Impact factor: 1.316

View more
  2 in total

1.  Determination of linear x-ray attenuation coefficients of pathological brain tissues and use of filters in tissue contrast enhancement in computed tomography.

Authors:  M Erdem Sagsoz; Fazlı Erdogan; Salih Z Erzeneoglu; İhsan Yuce
Journal:  Eurasian J Med       Date:  2010-08

2.  Beam hardening artifacts in micro-computed tomography scanning can be reduced by X-ray beam filtration and the resulting images can be used to accurately measure BMD.

Authors:  Jeffrey A Meganck; Kenneth M Kozloff; Michael M Thornton; Stephen M Broski; Steven A Goldstein
Journal:  Bone       Date:  2009-08-06       Impact factor: 4.398

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.